Use, Care, and Installation Guide www.zephyronline.com Anzio Island Luce Island ZAZ-M90CS ZLC-M90BS ZAZ-E42CS ZLC-E42BS Roma Island Ravenna Island ZRM-E36DS ZRE-M90ABSGG ZRM-E42DS ZRE-E42ABSGG Model number: + Serial Number: JUN20.0401 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet........................................ Mounting Height & Clearance................................. Ducting Options............................................................ Hood Specifications.................................................... Mounting the Hood...................................................... Ductless Recirculating............................................... 5 6 7 8-11 12-13 14 FEATURES & CONTROLS ICON Touch Controls.....................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Not for use over an outdoor grill. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com DUCTING A minimum of 6” round duct is recommended to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Use calculation worksheet to compute total duct work (Page 5). A n. mi . B n mi . C x a m D n. mi . E n mi . F x a m ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 6” to 7” or 8”. in.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
11” 10 5/8” 5 1/4” 25 9/16” FRONT SIDE 7 9/16” 3 9/16” C/L 5 15/ 16” C/L 8 1/8” 1 1/4” Z1C-00AZ min. ducted - 47” min. recirc. - 51” max. - 80” 1 3/16” 5 5/16” 16 9/16” 9 7/16” STANDARD min. ducted - 31 1/2” min. recirc. - 36” max. - 50” 35 7/16”, 41 15/16” 8 1/4” C/L AC In 13/16” 3 1/2” Installation – Hood Specification ZAZ www.zephyronline.
10 5/8” Z1C-00LC min. ducted - 47” min. recirc. - 51” max. - 80” 2 1/16” 12 3/8” 9 7/16” STANDARD min. ducted - 29” min. recirc. - 32 1/2” max.
” 14” 9 11/16” STANDARD min. ducted - 28” min. recirc. - 31” max. - 39” Z1C-01RM EXTENSION min. ducted - 50 1/2” min. recirc. - 50 1/2” max. - 80” 3” 11 3/16” 26 7/8” 35 7/8”, 41 7/8” 6" 9 7/16" 12 7/16" 11" ø 4 3/16" Installation – Hood Specification ZRM www.zephyronline.
Installation – Hood Specification ZRE 10 7/8” 24 1/2” (top of electrical box) STANDARD min. ducted - 28 1/2” min. recirc. - 28 1/2” max. - 38” Z1C-01REBS EXTENSION min. ducted - 48 1/2” min. recirc. - 48 1/2” max. - 78” 13 3/4” 5/16 ” 23 15/16” 3 9/16” 10 3/8” 35 3/16” 25 9/16” FRONT SIDE 8 3/4” 6” 11 5/8” 3 3/4” 4 3/16” C/L TOP of HOOD 5/8” 2 3/4” 8 1/4” 4 3/8” elec.
Installation – Mounting the Hood www.zephyronline.com ! CAUTION: At least two installers are required due to the weight and size of the hood. Top Support Frame Bottom Support Frame (secures to top of blower housing) Front Ceiling Joists back e Sid Key Holes 1 Wood Blocking 2 Top Support Frame front - facing controls FIG. C 3 Support Frame Arm FIG. B FRONT Bottom Support Frame B 4 BLOWER HOUSING Mounting Screws (pre-installed) Hood Body Cut-Out Shaded Area A XP022220 FIG. A FIG.
A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. Top Duct Covers Cable Lock FIG. E Bottom Duct Covers Bottom Support Frame FIG. D ! WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring. FIG. F 6.
Installation – Ductless Recirculating www.zephyronline.com Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and recirculated back within the home.
Lights Low/High/Off Adjust 5 Speed Levels 5 Lighted Glass Button Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). MODEL ZLC ONLY - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Features & Controls - ICON Touch Controls www.zephyronline.com 3 LIGHTS BUTTON - Lights have two levels, Low and High. - From off, press one time for Low. Press again for High. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters. - To reset: With hood off: hold the button for three seconds.
Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Maintenance – Lights www.zephyronline.com LED LIGHT STRIPS In the unlikely event that your LED strip fails, please contact Zephyr to order replacement parts. See list of parts and accessories page for part #’s and contact information. To replace LED light strip 1. Remove aluminum mesh filters. 2. Remove light panel by two screws. 3. Disconnect LED light strip quick connector. 4. Push in the two side clips on the ends of the LED strip. 5. Push LED light strip through the light panel opening.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board or control board wirings are disconnected. 3. Make sure the wirings at the switch board and control board are connected properly. 4.
ACT Conversion www.zephyronline.com Airflow Control Technology (ACT) Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT may not be necessary for your installation.
21 Fan Curve Diagrams
Fan Curve Diagrams www.zephyronline.
CIRCUIT DIAGRAM Power consumption shown for default 600 CFM blower configuration ACT 390 CFM - Fan Max. @ 2.3A ACT 290 CFM - Fan Max. @ 1.9A VOLTS HZ MAX. AMPS 120 60 4 CIRCUIT DIAGRAM 5A 250VAC ZLC A C 120V ZLC -E42BX-P 23 Power consumption shown for default 600 CFM blower configuration ACT 390 CFM - Fan Max. @ 2.3A ACT 290 CFM - Fan Max. @ 1.9A Wiring Diagram ZAZ, ZRM, ZRE VOLTS HZ MAX.
List of Parts & Accessories www.zephyronline.
Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace those that failed due to manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or replace parts before we elect to replace the Products.
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | 26 Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Anzio Island Luce Island ZAZ-M90CS ZLC-M90BS ZAZ-E42CS ZLC-E42BS Roma Island Ravenna Island ZRM-E36DS ZRE-M90ABSGG ZRM-E42DS ZRE-E42ABSGG Numéro de modèle : _________________ Numéro de série : _________________ JUN20.0401 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit............................ Espace libre et hauteur de montage.................... Options d’installation pour le conduit................... Spécifications de la hotte.......................................... Montage de la hotte.................................................... Reprise d’air sans conduit........................................ 5 6 7 8-10 11-13 14 COMMANDES ICON Commandes .....................................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage. Cet appareil n’est pas conçu pour être utilisé au-dessus d’un gril extérieur.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com CONDUIT D’AÉRATION Un conduit circulaire de 6” doit être utilisé pour assurer une circulation d’air maximale. N’utilisez que des conduits en métal rigide. Les conduits souples pourraient réduire la circulation d’air jusqu’à 50 %. A n. mi . B n mi . C x ma D n. mi . E n mi . F x ma in. ” max. 6 2 ”m 34 Utilisez la feuille de calcul pour obtenir la longueur totale du conduit (page 5).
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à tôle et isolez tous les joints avec du ruban adhésif en toile ou du ruban réflecteur certifié.
11” 10 5/8” 5 1/4” 25 9/16” DEVANT CÔTÉ 7 9/16” 3 9/16” C/L 5 15/ 16” C/L 8 1/8” 1 1/4” Z1C-00AZ min. ducted - 47” min. recirc. - 51” max. - 80” 1 3/16” 5 5/16” 16 9/16” 9 7/16” STANDARD min. ducted - 31 1/2” min. recirc. - 36” max. - 50” 35 7/16”, 41 15/16” 8 1/4” C/L AC In 13/16” 3 1/2” Installation – Spécifications de la hotte ZAZ www.zephyronline.
10 5/8” 9 7/16” STANDARD min. ducted - 29” min. recirc. - 32 1/2” max. - 46 1/2” 12 3/8” Z1C-00LC min. ducted - 47” min. recirc. - 51” max.
9 11/16” STANDARD min. ducted - 28” min. recirc. - 31” max. - 39” Z1C-01RM EXTENSION min. ducted - 50 1/2” min. recirc. - 50 1/2” max.
13 3/4” 5/16 ” 23 15/16” 3 9/16” Z1C-01REBS EXTENSION min. ducted - 48 1/2” min. recirc. - 48 1/2” max. - 78” 24 1/2” STANDARD min. ducted - 28 1/2” min. recirc. - 28 1/2” max. - 38” 35 3/16” 25 9/16” DEVANT CÔTÉ 8 3/4” 6” 11 5/8” 3 3/4” 4 3/16” C/L DESSUS de la HOTTE 5/8” 2 3/4” 8 1/4” 4 3/8” elec.
Installation – Montage de la hotte ! ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. Top Support Frame Cadre de fixation inférieur (est fixé à la partie supérieure du boîtier du ventilateur) Dos Front Encoches en trou Solives de plafond e Sid 1 Bloc de bois 2 Cadre de fixation supérieur Devant – commandes à l’avant FIG. C 3 Bras du cadre de fixation FIG.
Cadre de fixation supérieur Un raccord de câble (non inclus) pourrait également être exigé par les normes et réglementations locales. Informez-vous des exigences et des normes locales. Achetez et installez le connecteur approprié si nécessaire. Pièces de recouvrement supérieures Raccord de câble FIG. E Pièces de recouvrement inférieures Cadre de fixation inférieur FIG.
Installation – Reprise d’air sans conduit www.zephyronline.com La configuration de reprise sans conduit a été conçue pour les applications où il est impossible d’installer un conduit d’aération. Lorsque transformée, la hotte fonctionne comme une hotte de reprise d’air plutôt que comme un système d’évacuation d’air. Les vapeurs et fumées de cuisson sont aspirées et filtrées par un ensemble optionnel de filtres à charbon. L’air est ensuite purifié et redirigé à l’intérieur de la maison.
Lumières: faible / élevée / éteinte Choix de 5 vitesses ZLC seulement 5 Touche d’illumination du verre Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
Commandes - ICON Commandes www.zephyronline.com 3 TOUCHE DE CONTRÔLE DES LUMIÈRES - Il existe deux intensités: basse et haute. - Lorsque les lumières sont éteintes, appuyez une fois pour les allumer à faible intensité. Appuyez à nouveau pour les mettre en hauteur. Appuyez à nouveau pour les désactiver.
Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide. Après le nettoyage, vous pouvez polir les surfaces avec des produits de polissage à acier inoxydable non abrasifs pour redonner de l’éclat et du lustre aux surfaces.
Maintenance - Lumières Bandes de lumière LED Dans l’éventualité peu probable d’une défaillance de votre bande de LED, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées. Pour remplacer la bande lumineuse à LED 1. Retirez les filtres à mailles en aluminium. 2. Retirez le panneau d’éclairage à l’aide de deux vis. 3. Débranchez le connecteur rapide du bandeau lumineux à LED. 4.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’appareil est allumée 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 2. Vérifiez que le branchement de l’appareil a été fait correctement 3. Les fils électriques du tableau de contrôle et de commande sont débranchés 3.
Conversion De La ACT www.zephyronline.com Technologie de contrôle du débit d’air (ACT) Certains codes et règlements limitent la quantité maximale de pi3/min qu’une hotte peut extraire. La ACT permet de contrôler la quantité maximale de pi3/min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux.
21 Tableau De Rendement Du Ventilateur
Tableau De Rendement Du Ventilateur www.zephyronline.
ZAZ, ZRM, ZRE Schéma De Câblage NOIR GRIS BRUN BLEU JAUNE JAUNE BLANC VERTE NOIR/BLANC VERTE CORPS JAUNE ROUGE ROUGE JAUNE GRIS BRUN BLEU BLANC ACT 390 CFM - Ventilateur Max. @ 2.3A ACT 290 CFM - Ventilateur Max. @ 1.9A BLANC CORPS Consommation montré pour défaut de configuration du ventilateur 600 CFM VOLTS HZ MAX. AMPS 120 60 4 ZLC Schéma De Câblage ACT 390 CFM - Ventilateur Max. @ 2.3A ROUGE JAUNE JAUNE JAUNE ACT 290 CFM - Ventilateur Max. @ 1.
Listes des pièces et des accessoires www.zephyronline.
Une preuve de la date d’achat originale est nécessaire pour obtenir du service lorsque le produit est sous garantie Garantie limitée POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de
www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.