DUCTING
A minimum of 6” round ducting must be used to 
PDLQWDLQPD[LPXPDLUÀRZHႈFLHQF\
Always use rigid type metal ducts only. Flexible 
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
8VHFDOFXODWLRQZRUNVKHHWWRFRPSXWHWRWDOGXFW
ZRUN
ALWAYS, when possible, reduce the number of 
transitions and turns. If a long duct run is required, 
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far 
away from opening and as far apart, between 2, 
as possible.
36”
24” min.
32” max.
0RXQWLQJKHLJKWIURPWRSRIFRRNLQJVXUIDFHWR
bottom of hood should be no less than 24” and no 
more than 32”.
It is important to install the hood at the proper 
mounting height. Hoods mounted too low could 
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will 
ORVHSHUIRUPDQFHDQGHႈFLHQF\
If available, also refer to range manufacturer’s 
height clearance requirements and recommended 
KRRGPRXQWLQJKHLJKWDERYHUDQJH$OZD\VFKHFN
\RXUORFDOFRGHVIRUDQ\GLႇHUHQFHV
DAMAGE-SHIPMENT / INSTALLATION:
•  Please fully inspect unit for damage before 
installation.
•  If the unit is damaged in shipment, return 
the unit to the store in which it was bought 
for repair or replacement.
•  If the unit is damaged by the customer, 
repair or replacement is the responsibility 
of the customer.
•  If the unit is damaged by the installer 
(if other than the customer), repair of 
replacement must be made by arrangement 
between customer and installer.
Installation – Mounting Height & Clearance