WWW.ZEPHYRONLINE.COM Monsoon I AK9228BS, AK9234BS, AK9240BS, AK9246BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology OCT20.
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-9 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................5-8 Operation ........................................................................................... 8 Electrical Requirements ........................................................
CORE Safety Information MONSOON I INSERT Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can cause severe bodily injury or death.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS General Safety WARNING To reduce the risk of fire or electric shock, do not use this fan with any solid-state control device. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
CORE Safety Information MONSOON I INSERT READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. b) Always turn hood ON when cooking at high heat or when flambeing food. (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’). c) Clean ventilating fans frequently.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting.
CORE Safety Information MONSOON I INSERT READ AND SAVE THESE INSTRUCTIONS CAUTION Ź To reduce risk of fire and to properly exhaust air outside, do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages. Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS Ź This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. Ź A cable locking connector (not supplied) might also be required by local codes.
CORE List of Materials MONSOON I INSERT Parts Supplied (AK9228BS & AK9234BS) Quantity 1 2 2 1 1 2 1 1 Part Liner hood body Pro baffle filters LumiLight LED, 6W (pre-installed) Internal blower (pre-installed) 8” round adapter w/ damper Horizontal ducting blower mount brackets Top rectangular cover plate Hardware package #8 x 1/2” (12) Wire Caps (3) Parts Supplied (AK9240BS & AK9246BS) Quantity 1 2 3 2 4 1 1 1 Part Liner hood body Pro baffle filters (AK9240BS) Pro baffle filters (AK9246BS) LumiLight LED,
Installation Instructions ZEPHYRONLINE.COM Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
CORE Installation Instructions MONSOON I INSERT Mounting Height, Clearance, & Ducting n..
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 8” round for AK9228BS and AK9234BS must be used to maintain maximum air flow efficiency. A minimum of 10” round duct for AK9240BS and AK9246BS must be used to maintain maximum air flow efficiency. Horizontal ducting is not available for AK9240BS and AK9246BS. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
CORE Installation Instructions MONSOON I INSERT Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM Ů 2 34 2-3/8 -3/ ”, 8” , 4 28-3 0- /8” 3/8 ” ” 12 3” 12” 2 40 8-3/8 -3/ ”, 8” , 4 34-3 6-3 /8” /8 ” 19 1/4 ” 2” (28”) 14-1/4” (34”) 17-1/4” (40”) 20-1/4” (46”) 23-1/4” (28”) 9-1/4” (34”) 12-1/4” (40”) 15-1/4” (46”) 18-1/4” * 1-1/2” (28”, 34”) 5-5/8” (40”, 46”) 5-7/8” 3/4 View (28”, 34”)Ø 7-3/4” (40”, 46”)Ø 9-3/4” elec.
CORE Installation Instructions MONSOON I INSERT Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Preparation & Installation CAUTION At least two installers are required due to the weight and size of the liner. 1. Remove all packing materials and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. 2. Cut out an opening in the bottom of the cabinet by following the dimensions in FIG. B.
CORE Installation Instructions MONSOON I INSERT Preparation & Installation 4. Lift liner into bottom opening of cabinet and secure to interior of cabinet using (8) #8 x 1/2” stainless steel screws; (4) screws in the front and (4) screws in the sides. FIG. D. 5. Finalize installation of electrical and duct work. Seal duct work with certified aluminum duct tape. Power on liner, check for leaks around duct tape and verify proper operation. 6.
Installation Instructions ZEPHYRONLINE.COM Vertical Ducting Preparation 1. Remove baffle filters by: 1) Pulling filter toward front of liner. 2) Pivoting rear of filter down. 1 2 1 1 2. Remove grease tray by: 1) Pulling up on tray to release from bottom panel. 2) Lifting tray out of liner body. 2 3. (If applicable) Remove left and right side-spacer panels by removing (2) screws from behind each panel.
CORE Installation Instructions MONSOON I INSERT Vertical Ducting Preparation 1 Bottom Panel Screws 2 4. Remove bottom panel by: 1) Removing (2) screws from left and right sides of bottom panel. 2) Pulling bottom panel toward front of liner to release from locking tabs. Locking Tabs 5. Secure 8” round adapter or 10” round adapter to top of liner by (4) M4 x 6mm screws. 6. Vertical ducting preparation is complete. Refer to page 18, step 4 to complete installation.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Preparation AK9228BS & AK9234BS Models Only 1. Remove baffle filters by: 1) Pulling filter toward front of liner. 2) Pivoting rear of filter down. 1 2 1 1 2. Remove grease tray by: 1) Pulling up on tray to release from bottom panel. 2) Lifting tray out of liner body. 2 3. (If applicable) Remove left and right side-spacer panels by removing (2) screws from behind each panel.
CORE Installation Instructions MONSOON I INSERT Horizontal Ducting Preparation AK9228BS & AK9234BS Models Only 1 Bottom Panel Screws 2 4. Remove bottom panel by: 1) Removing (2) screws from left and right sides of bottom panel. 2) Pulling bottom panel toward front of liner to release from locking tabs. Locking Tabs 5. Disconnect blower molex plug. 6. Remove blower from liner by removing the (4) 3/16” x 3/8” screws from the top of the liner. Set screws aside for later usage.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Preparation AK9228BS & AK9234BS Models Only 7. Using a flat head screwdriver, remove 8” round knock-out plates at the back of the liner. 8. Remove the round ducting knockout. 9. Place top rectangular cover plate over opening on top of the liner. NOTE: Make sure the cover plate tabs are on top of the cover plate as shown. From inside the liner, secure plate to top of liner with (2) 3/16 x 3/8 screws.
CORE Installation Instructions MONSOON I INSERT Horizontal Ducting Preparation AK9228BS & AK9234BS Models Only 10. From inside the liner, push 8” round adapter through the back knock-out and secure to interior back wall of liner with (4) M4 x 6mm screws. 11. Secure (2) horizontal ducting blower brackets to blower as shown above by using the (4) 3/16” x 3/8” screws previously removed from Page 22, Step 6; (2) screws for each bracket. 2 1 24 1 12.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Preparation AK9228BS & AK9234BS Models Only 13. Secure blower to captive nuts on interior back wall of liner with (8) 3/16” x 3/8” screws, (4) screws for each bracket. Seal any gaps around the knock-out plate by using certified aluminum duct tape. Plug in blower molex plug. Horizontal ducting preparation is now complete. Refer to Page 18, Step 5 to complete installation.
CORE Features & Controls MONSOON I INSERT Touch Controls 1 Blower On/Off 5 Display (speed level, delay off, filter clean) 4 Lights Low/High/Off 2 Adjust 6 Speed Levels 3 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations.
Features & Controls ZEPHYRONLINE.COM Touch Controls Baffle Filter Clean Reminder A set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The BaffleFilter Clean reminder function in the microprocessor will automatically indicate by a flashing F when the baffle filters need to be cleaned after every 60 hours of use.
CORE Features & Controls MONSOON I INSERT RF Remote Control FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example use only shielded interface cables when connecting to computer or peripheral device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
Features & Controls ZEPHYRONLINE.COM RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. E. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the liner. FIG.
CORE Maintenance MONSOON I INSERT Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Maintenance ZEPHYRONLINE.COM Ų ĕ Ę ė 1. Place filter into top groove of the liner as shown and pull towards front of liner using handles. 2. Pivot back of filter upwards so it is angled in the liner. 3. Push filter into channel on back of liner to lock into place. 1 2 FIG. G Removing the Grease Tray Grease tray has a hooked lip that attaches to bottom panel top edge. Remove grease tray by: 1. Pull up on tray to release from bottom panel. FIG. H1 2. Pull tray out of liner body.
CORE Maintenance MONSOON I INSERT LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. I): 1. Remove baffle filters. 2. Remove light panel by five screws. 3. Disconnect LED light quick connector. 4. Push in the two side clips on the ends of the LED light. 5. Push LED light through the light panel opening. Push the clip FIG.
ACT™ Conversion ZEPHYRONLINE.COM ů Ĭ Ļĭ Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; AK9228BS & AK9234BS - 290 or 390 CFM, AK9240BS & AK9446BS - 590 or 390 CFM.
CORE ACT™ Conversion MONSOON I INSERT Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. J. 2. Change plastic jumper positioning as shown in FIG. K to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
ACT™ Conversion ZEPHYRONLINE.COM Enabling ACT™ 1. PC board located behind the light panel. 2. (If applicable) Remove both spacer panels by 2 screws for each spacer panel. 3. Remove 5 screws attaching light panel. FIG. J Jumper Pins 7 5 3 1 Plastic Jumper 8 6 4 2 J u m p e r 5 - 6 or 7-8 DEFAULT POSITION Default Max. Blower CFM 7 5 3 1 8 6 4 2 PC Board 7 5 3 1 8 6 4 2 Jumper 3-4 Max. Blower CFM AK9228BS & AK9234BS - 390 AK9240BS & AK9246BS - 590 7 5 3 1 8 6 4 2 Jumper 1-2 Max.
CORE Wiring Diagram MONSOON I INSERT AK9228BS & AK9234BS CIRCUIT DIAGRAM RED YELLOW YELLOW MOTOR YELLOW BLUE BROWN GREY RED YELLOW YELLOW WHITE GREEN BODY WHITE BLACK GREEN BODY TRANSFORMER ACT 390 CFM - Fan Max. 355W @ 3.0A ACT 290 CFM - Fan Max. 255W @ 2.
Wiring Diagram ZEPHYRONLINE.COM AK9240BS CIRCUIT DIAGRAM GREEN BODY YELLOW YELLOW MOTOR YELLOW BLUE BROWN GREY RED YELLOW YELLOW RED WHITE YELLOW YELLOW GREY BROWN BLUE B/W GREEN BODY WHITE OPTIONAL DUAL FAN MOTOR YELLOW RED YELLOW GREY BROWN BLUE YELLOW RED WHITE WHITE BLACK GREEN BODY TRANSFORMER ACT 590 CFM - Fan Max. 556W @ 4.6A ACT 390 CFM - Fan Max. 381W @ 3.
CORE Wiring Diagram MONSOON I INSERT AK9246BS CIRCUIT DIAGRAM GREEN BODY YELLOW YELLOW MOTOR YELLOW BLUE BROWN GREY RED YELLOW YELLOW RED WHITE YELLOW YELLOW GREY BROWN BLUE B/W GREEN BODY WHITE OPTIONAL DUAL FAN MOTOR YELLOW RED YELLOW GREY BROWN BLUE YELLOW RED WHITE WHITE BLACK GREEN BODY TRANSFORMER ACT 590 CFM - Fan Max. 556W @ 4.6A ACT 390 CFM - Fan Max. 381W @ 3.
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
CORE Troubleshooting MONSOON I INSERT Possible Problem The hood is not venting out properly. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 24” and 36” range. Close all the windows and doors to eliminate the outside wind flow. The unit turns on by itself.
List of Parts & Accessories ZEPHYRONLINE.COM Description Replacement Parts LumiLight LED, 6W Pro Baffle Filter, each RF Remote Control Part Number Z0B0047 50210039 14000005 Optional Accessories Make-up Air Kit (600 CFM) Make-up Air Kit (1200 CFM) MUA006A MUA010A To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368.
Limited Warranty ZEPHYRONLINE.
CORE Product Registration MONSOON I INSERT Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Monsoon I AK9228BS, AK9234BS, AK9240BS, AK9246BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology OCT20.
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-9 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................5-8 Opération ........................................................................................... 8 Exigences électriques .......................................................
CORE Consignes de sécurité MONSOON I INSÉRER Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. Voici le symbole d’alerte à la sécurité. Ce symbole vous informe de possibles dangers qui pourraient entraîner de graves lésions corporelles ou la mort.
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS Sécurité générale ATTENTION Pour réduire le risque d’incendie ou de choc électrique, n’utilisez pas ce ventilateur avec un dispositif de commande à semiconducteurs. ATTENTION AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, contactez le fabricant.
CORE Consignes de sécurité MONSOON I INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS ATTENTION AVERTISSEMENT - POUR RÉDUIRE LE RISQUE D’INCENDIE DE GRAISSE SUR LE HAUT DE CUISINIÈRE: a) Ne laissez jamais les unités de surface sans surveillance à des réglages élevés. Les débordements provoquent de la fumée et des débordements graisseux qui peuvent s’enflammer. Chauffer les huiles lentement à des réglages faibles ou moyens.
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS ATTENTION AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ CE QUI SUIT: a) Les travaux d’installation et le câblage électrique doivent être effectués par des personnes qualifiées conformément à tous les codes et normes applicables, y compris la construction résistant au feu.
CORE Consignes de sécurité MONSOON I INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT Ź Pour réduire les risques d’incendie et pour évacuer correctement l’air extérieur, ne pas évacuer l’air évacué dans les espaces à l’intérieur des murs, plafonds, greniers, vides sanitaires ou garages. Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples.
Consignes de sécurité ZEPHYRONLINE.COM LISEZ ET CONSERVEZ CES INSTRUCTIONS Ź Cet appareil nécessite une alimentation électrique de 120 V à 60 Hz et est connecté à un circuit de dérivation individuel correctement mis à la terre protégé par un disjoncteur de 15 ou 20 ampères ou un fusible temporisé. Le câblage doit être à 2 fils avec mise à la terre. Veuillez également vous référer au schéma électrique du produit.
CORE Liste de matériel MONSOON I INSÉRER Pièces fournies (AK9228BS et AK9234BS) Quantité 1 2 3 2 1 1 2 1 Pièces fournies (AK9240BS et AK9246BS) Partie Quantité Doublure du corps de la capuche 1 Filtres à chicane pro 2 LumiLight LED, 6 W (pré-installé) 3 Ventilateur interne (pré-installé) 2 Adaptateur rond de 8 po avec amortisseur 4 Supports de montage de ventilateur à conduit horizontal 1 Plaque de recouvrement rectangulaire 1 supérieure Pack matériel 1 (12) #8 x 1/2” (3) capuchons de connexion Part
Instructions d’installation ZEPHYRONLINE.COM Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect.
CORE Instructions d’installation MONSOON I INSÉRER Hauteur de montage, dégagement et gaine in..
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un diamètre minimum de 8 po pour les AK9228BS et AK9234BS doit être utilisé pour maintenir une efficacité maximale du débit d’air. Un conduit rond d’au moins 10 po pour AK9240BS et AK9246BS doit être utilisé pour maintenir une efficacité maximale du débit d’air. La gaine horizontale n’est pas disponible pour les AK9240BS et AK9246BS. Utilisez toujours des conduits métalliques de type rigide uniquement.
CORE Instructions d’installation MONSOON I INSÉRER Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM ¯ Ů 2 34 2-3/8 -3/ 8 p po, o, 2840 3/8 -3/ 8 p po o o p 12 3p o 12 po 2 40 8-3/8 -3/ 8 p po, o, 3446 3/8 -3/ 8 p po o 1 o 4p 1/ 9- (28 po) 14-1/4 po (34 po) 17-1/4 po (40 po) 20-1/4 po (46 po) 23-1/4 po (28 po) 9-1/4 po (34 po) 12-1/4 po (40 po) 15-1/4 po (46 po) 18-1/4 po 2 po * 1-1/2 po (28 po, 34 po) 5-5/8 po (40 po, 46 po) 5-7/8 po Vue 3/4 (28 po, 34 po)Ø 7-3/4 po (40 po, 46 po)Ø 9-3/4 po elec.
CORE Instructions d’installation MONSOON I INSÉRER Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Préparation et installation ATTENTION Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la doublure. C ou (A (AK K92 pé 4 (AK 924 6) (AK 92 0 92 34) ) 4 46-1 / 28 34 0-1/2 2 po ) 2. Découpez une ouverture dans le bas de l’armoire en suivant les dimensions de la FIG. B. Si vous conduisez le revêtement monobloc horizontalement, découpez également une ouverture à l’arrière de l’armoire (le cas échéant). FIG C.
CORE Instructions d’installation MONSOON I INSÉRER Préparation et installation 4. Soulevez la doublure dans l’ouverture inférieure de l’armoire et fixez-la à l’intérieur de l’armoire à l’aide de (8) vis en acier inoxydable n°8 x 1/2 po; (4) vis à l’avant et (4) vis sur les côtés. figure. RÉ. 1/4 po REMARQUE: Si l’accès au dessus de la gaine n’est pas disponible après l’installation, il se peut que le raccordement électrique et du conduit de conduits doive être effectué avant d’installer la gaine.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits verticaux 1. Retirez les filtres déflecteurs en: 1) Tirant le filtre vers l’avant de la doublure. 2) Pivotement de l’arrière du filtre vers le bas. 1 2 1 1 2. Retirez le plateau à graisse en: 1) Tirant sur le plateau pour le dégager du panneau inférieur. 2) Soulever le plateau hors du corps de la doublure. 2 3. (Le cas échéant) Retirez les panneaux d’entretoise latéraux gauche et droit en retirant les (2) vis derrière chaque panneau.
CORE Instructions d’installation MONSOON I INSÉRER Préparation des conduits verticaux 1 Vis du panneau inférieur 2 4. Retirez le panneau inférieur en: 1) Retirez les (2) vis des côtés gauche et droit du panneau inférieur. 2) Tirer le panneau inférieur vers l’avant de la doublure pour le dégager des languettes de verrouillage. Verrouillage des onglets 5. Fixez l’adaptateur rond de 8 po ou l’adaptateur rond de 10 po sur le dessus de la doublure à l’aide de (4) vis M4 x 6 mm. 6.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits horizontaux Modèles AK9228BS et AK9234BS uniquement 1. Retirez les filtres déflecteurs en: 1) Tirant le filtre vers l’avant de la doublure. 2) Pivotement de l’arrière du filtre vers le bas. 1 2 1 1 2. Retirez le plateau à graisse en: 1) Tirant sur le plateau pour le dégager du panneau inférieur. 2) Soulever le plateau hors du corps de la doublure. 2 3.
CORE Instructions d’installation MONSOON I INSÉRER Préparation des conduits horizontaux Modèles AK9228BS et AK9234BS uniquement 1 Vis du panneau inférieur 2 4. Retirez le panneau inférieur en: 1) Retirez les (2) vis des côtés gauche et droit du panneau inférieur. 2) Tirer le panneau inférieur vers l’avant de la doublure pour le dégager des languettes de verrouillage. Verrouillage des onglets 5. Débranchez la fiche molex du ventilateur. 6.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits horizontaux Modèles AK9228BS et AK9234BS uniquement 7. À l’aide d’un tournevis à tête plate, retirez les plaques à défoncer rondes de 8 po à l’arrière de la doublure. 8. Retirez le débouchure du conduit rond. 9. Placez la plaque de recouvrement rectangulaire supérieure sur l’ouverture au-dessus de la doublure.
CORE Instructions d’installation MONSOON I INSÉRER Préparation des conduits horizontaux Modèles AK9228BS et AK9234BS uniquement 10. (Pour les conduits ronds) Depuis l’intérieur de la gaine, poussez l’adaptateur rond de 8 po à travers la découpe arrière et fixez à la paroi arrière intérieure de la gaine avec (4) vis M4 x 6 mm. 11.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits horizontaux Modèles AK9228BS et AK9234BS uniquement 13. Fixez le ventilateur aux écrous captifs sur la paroi arrière intérieure du revêtement avec (8) vis 3/16 po x 3/8 po, (4) vis pour chaque support. Scellez tous les espaces autour de la plaque d’éjection à l’aide de ruban adhésif en aluminium certifié. Branchez la prise molex du ventilateur. La préparation des conduits horizontaux est maintenant terminée.
CORE Fonctionnalités et commandes MONSOON I INSÉRER Commandes tactiles 1 Ventilateur Marche/Arrêt 5 Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) 4 Lumière: faible, élevée, désactivée 2 Choix de 6 vitesses 3 Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1.
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres.
CORE Fonctionnalités et commandes MONSOON I INSÉRER Télécommande RF Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement. (Exemple - utilisez uniquement des câbles d’interface blindés lors de la connexion à un ordinateur ou à un périphérique. Cet appareil est conforme à la partie 15 des règles FCC.
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. E. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile. Remarque: le support de télécommande ne charge pas la télécommande RF.
CORE Entretien MONSOON I INSÉRER Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
Entretien ZEPHYRONLINE.COM Ů ¯ů ĕ Ę ė 1. Placez le filtre dans la rainure supérieure de la doublure comme illustré et tirez vers l’avant de la doublure à l’aide des poignées. 2. Faites pivoter l’arrière du filtre vers le haut pour qu’il soit incliné dans la doublure. 3. Poussez le filtre dans le canal à l’arrière de la doublure pour le verrouiller en place. 1 2 FIG.
CORE Entretien MONSOON I INSÉRER LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées. Retrait de la LED LumiLight (FIG. I): 1. Retirer les filtres déflecteurs 2. Retirez le panneau lumineux par cinq vis. 3. Débranchez le connecteur rapide de la lumière LED. 4.
Conversion ACT™ ZEPHYRONLINE.COM Technologie de contrôle du débit d’air (ACT™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisinière peut déplacer. ACT ™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de kits d’air d’appoint coûteux.
CORE Conversion ACT™ MONSOON I INSÉRER Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes illustrées à la FIG. J. 2. Changez le positionnement du cavalier en plastique comme illustré à la FIG. K pour régler le CFM maximum souhaité du ventilateur. 3. Réinstallez la carte de circuit imprimé et poursuivez l’installation de la hotte. 4.
Conversion ACT™ ZEPHYRONLINE.COM Activer ACT™ 1. Carte électronique située derrière le panneau lumineux. 2. (Le cas échéant) Retirez les deux panneaux d'espacement par 2 vis pour chaque panneau d'espacement. 3. Retirez les 5 vis fixant le panneau lumineux. FIG.
CORE Schéma de câblage MONSOON I INSÉRER AK9228BS & AK9234BS SCHÉMA ROUGE JAUNE JAUNE MOTEUR JAUNE BLEU MARRON GRIS ROUGE JAUNE JAUNE BLANC VERT CORPS WHITE NOIR VERT CORPS TRANSFORMATEUR ACT 390 CFM - Ventilateur Max. 355 W à 3,0 A ACT 290 CFM - Ventilateur Max.
Schéma de câblage ZEPHYRONLINE.COM AK9240BS SCHÉMA JAUNE MOTEUR VERT CORPS JAUNE JAUNE MOTEUR JAUNE BLEU MARRON GRIS ROUGE JAUNE JAUNE ROUGE BLANC JAUNE JAUNE GRIS MARRON BLEU B/W VERT CORPS BLANC DOUBLE VENTILATEUR EN OPTION ROUGE JAUNE GRIS MARRON BLEU JAUNE ROUGE BLANC BLANC NOIR VERT CORPS TRANSFORMATEUR ACT 590 CFM - Ventilateur Max. 556W à 4,6A ACT 390 CFM - Ventilateur Max.
CORE Schéma de câblage MONSOON I INSÉRER AK9246BS SCHÉMA JAUNE VERT CORPS JAUNE MOTEUR JAUNE BLEU MARRON GRIS ROUGE JAUNE JAUNE ROUGE BLANC JAUNE MOTEUR JAUNE JAUNE GRIS MARRON BLEU B/W VERT CORPS BLANC DOUBLE VENTILATEUR EN OPTION ROUGE JAUNE GRIS MARRON BLEU JAUNE ROUGE BLANC BLANC NOIR VERT CORPS TRANSFORMATEUR ACT 590 CFM - Ventilateur Max. 556W à 4,6A ACT 390 CFM - Ventilateur Max.
Dépannage ZEPHYRONLINE.COM Problème possible Après l'installation, l'unité ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L'unité vibre. Cause possible Solutions La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement. Les câblages du tableau de commande ou du tableau de commande sont déconnectés.
CORE Dépannage MONSOON I INSÉRER Problème possible La hotte ne s'échappe pas correctement. Cause possible Solutions Utilisation de la mauvaise taille de conduit. Changer la gaine à la bonne taille La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la table de cuisson et le bas de la hotte dans les limites de 24 po et 36 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange LumiLight LED, 6 W Filtre à chicane pro (chacun) Télécommande RF Numéro d’article Z0B0047 50210039 14000005 Accessoires optionnels Kit d'air d'appoint (600 CFM) Kit d'air d'appoint (1200 CFM) MUA006A MUA010A Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com ou appelez-nous au 1.888.880.8368.
Garantie limitée ZEPHYRONLINE.
CORE Enregistrement du produit MONSOON I INSÉRER 44 Monsoon I Guide d’utilisation, d’entretien et d’installation