Use, Care, and Installation Guide www.zephyronline.com Napoli ZNA-M90BS ZNA-E42BS Model number: Serial Number: Date of Purchase: Sales Dealer: MAY11.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Hood Specifications ................................................... Mounting the Hood ..................................................... Ductless Recirculating .............................................. 5 6 7 8 9-10 11 FEATURES & CONTROLS Touch Controls ...............................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Not for use over an outdoor grill. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect. 90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect. 45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible. Minimum mount height between range top to hood bottom should be no less than 26”. A n. mi . B n mi . C x ma D n. mi . E n mi .
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation – Hood Specification www.zephyronline.com 9 13/16” 12 13/16” STANDARD min. ducted - 32” min. recirc. - 36 1/2” max. - 50” 10 5/16” 9 9/16” Z1C-01NA min. ducted - 49” min. recirc. - 53 1/2” max.
Bottom Support Frame (secures to top of blower housing) back Key Holes Ceiling Joists Front Sid 1 Wood Blocking 2 Top Support Frame front - facing controls FIG. C 3 Support Frame Arm FRONT FIG. B Bottom Support Frame B 4 Mounting Screws (pre-installed) Hood Body Cut-Out Shaded Area A XP022220 FIG. A FIG. G 1. Determine mounting location on ceiling and temporarily tape paper template (included with the hood) to the ceiling.
Installation – Mounting the Hood www.zephyronline.com Cable Lock 2 Top Support Frame Top Duct Covers 1 5 Thick Trim Piece A cable locking connector (not supplied) might be required by local codes. Check with local requirements and codes, purchase and install appropriate connector if necessary. 4 Bottom Duct Covers Thin Trim Piece 3 Cable Lock FIG. E Bottom Support Frame FIG. D FIG.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, if possible. The hood is most effective and efficient as an exhaust hood. Only when the exhaust option is not possible should you recourse to converting the hood into a recirculating hood. When converted to be a recirculating hood, a set of charcoal filters are required on top of its standard aluminum mesh filter set. Order according to its part number below.
Features & Controls - Touch Controls www.zephyronline.com Power / Delay Off Display (speed level, delay off, filter clean/change,clean air) clean mesh filter clean air replace charcoal filter Adjust 6 Speed Levels Lights On/Dim/Off 1 Power / Delay Off Button Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
Charcoal Filter Replace Indicator (disabled by default, must be enabled if recirculating hood) - To enable Charcoal Filter Replacement Function: - With hood off, hold Button and Button simultaneously for three seconds. The Graphic will illuminate for three seconds indicating the Charcoal Filter Replacement Function is enabled. - To disable Charcoal Filter Replacement Function: - With hood off, hold Button and Button simultaneously for three seconds.
Maintenance – Hood and Filter Cleaning www.zephyronline.com SURFACE MAINTENANCE: Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
Wiring & Fan Curve Diagrams www.zephyronline.com Model: ZNA-M90BS/E42BS Voltage: 120V 60Hz Power consumption Total: Max. 215W @ 3.5A Lamp: Max. 3Wx4 Fan: Max. 203W THERMALLY PROTECTED U V W U V W 5A 250V AC-N ON/OFF DOWN UP AC-L LAMP Pressure (inAq) Blower fan curve AC input: 120V 60Hz Outlet diameter : 8" 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.1 2 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.
PART# Replacement Parts Light Bulb 3W LED (each) Aluminum Mesh Filter (each) Z0B-0032 50200027 Optional Accessories Recirculating Kit Replacement Charcoal Filter (each) Extension Duct Cover ZRC-00NA Z0F-C002 Z1C-01NA To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty