INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Hood Specifications ................................................... Mounting the Range Hood ...................................... Ductless Recirculating .............................................. 5 6 7 8 9 10 FEATURES & CONTROLS Touch Controls ...........................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.com MODELS: ZMO-E30AS, ZMO-M90AS PARTS SUPPLIED 1 - Hood with internal blower 1 - Aluminum mesh filter 1 - Duct cover assembly (top and bottom) 1 - Duct cover wall bracket 4 - 3W LED light bulbs 1 - 8” round backdraft damper (pre-installed) 1 - Hardware package HARDWARE PACKAGE CONTENTS M3.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect. 90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect. 45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible. A n. mi . B n mi . C x ma D n. mi . E n i m .F x ma Minimum mount height between range top to hood bottom should be no less than 26”. in. ” m x.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
front of hood side of hood 13 3/8” 12 3/8” STANDARD min. ducted - 27” min. recirc. - 31” max. - 50” Z1C-00MO min. ducted - 41 1/2” min. recirc. - 45 1/2” max. - 80” 1 3/16” 16 15/16” 6 5/16” 8 3/8” 29 15/16”, 35 7/16” 22 1/8” 4 5/8” top of hood 5 1/16” Installation – Hood Specifications www.zephyronline.
1. Measure from range top to hood bottom and mark line A. (26” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line B. (17 1/2” from line A) 4. Mark mounting spread from C/L. (11 1/4”) 5. Fasten (2) M6 x 1-1/2” screws into studs on line B but do not tighten all the way. Note: Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes before using wall anchors. 6.
Installation – Ductless Recirculating www.zephyronline.com Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and recirculated back within the home.
Display (speed level, delay off, filter clean/change,clean air) clean mesh filter clean air replace charcoal filter Adjust 6 Speed Levels Lights On/Dim/Off 1 Power / Delay Off Button Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Features & Controls – User Interface www.zephyronline.com Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “clean mesh filter” will illuminate indicating it is time to clean the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “clean mesh filter” will turn off and the 30 hour timer will reset.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR MODENA WALL Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3.
U V W U V W 5A 250V AC-N ON/OFF DOWN UP AC-L LAMP Pressure (inAq) Blower fan curve AC input: 120V 60Hz Outlet diameter : 8" 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.1 2 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 625 650 675 700 725 750 Flow rate (CFM) Wiring & Fan Curve Diagrams Model: ZMO-E30/M90AS Voltage: 120V 60Hz Power consumption Total: Max. 215W @ 3.5A Lamp: Max.
List of Materials www.zephyronline.com DESCRIPTION PART# Replacement Parts Light Bulb 3W LED (each) Aluminum Mesh Filter (each) Z0B-0032 50200042 Optional Accessories Recirculating Kit Replacement Charcoal Filter Duct Cover Extension ZRC-00MO Z0F-C002 Z1C-00MO To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty