Use, Care, and Installation Guide www.zephyronline.com Milano Island ZML-M90BG ZML-M90BS ZML-E42BG ZML-E42BS Model number: Serial Number: MAY11.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Hood Specifications ................................................... Mounting the Hood ..................................................... Ductless Recirculating .............................................. 5 6 7 8 9-11 12 FEATURES & CONTROLS Touch Controls ...............................
Important Safety Notice READ AND SAVE THESE INSTRUCTIONS www.zephyronline.com WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE IN OUTDOOR COOKING ENVIRONMENTS. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect. 90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect. 45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible. A n. mi . B n i m .C x ma D n. mi . E n i m .F x ma Minimum mount height between range top to hood bottom should be no less than 26”.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
12 15/16” 12 3/4” 9 11/16” 6 11/16” STANDARD min. ducted - 28 1/2” min. recirc. - 32 1/2” max. - 50” 14 1/8” Z1C-03ML min. ducted - 44” min. recirc. - 48 1/2” max. - 82” 23 15/16” 25 9/16” 35 5/16”, 42” FRONT SIDE 10 9/16” 9 11/16” 1 1/4” C/L C/L 4” AC In 71 10 15/16” C/L 5/1 6” 2 3/16” 5 5/16” 4 13/16” 5/8” Installation – Hood Specifications www.zephyronline.
PAPER TEMPLATE Front of Hood B Cut-Out Shaded Area Ceiling Joists Wood Blocking 1 fron t 3 Top Support Frame A 2 FIG. B Bottom Support Frame FRONT FRONT 6 5 1 Hood Body/Canopy 4 2 FIG. C FIG. A Hood is intended to be mounted to a finished ceiling. 1. Ceiling Preparation: Determine hood mounting location and temporarily tape paper template (incluided with the hood) to the ceiling. Cut-out internal shaded area of template to allow the ductng and electrical to pass through.
Installation – Mounting the Hood www.zephyronline.com ! CAUTION: At least two installers are required due to the weight and size of the hood. BLOWER HOUSING ELECTRONICS MOUNTING BRACKET FIG. E 1 1 2 FIG. F FIG. D 5. Remove tape securing electronics mounting bracket to hood. (FIG. D, #1) Remove (3) screws from top of hood body and set screws aside. Position electronics mounting bracket as show in (FIG. D, #2) and secure to hood body using the (3) previously removed screws. 6.
1 Top support frame Top duct covers 2 5 Thick trim piece (top) 4 Thin trim piece (bottom) Bottom duct covers 3 Bottom support frame FIG. G 10. *Secure top duct covers (with louver holes) to top support frame using (2) M4 x 8 screws. (FIG. G, #1). Note: If using hood in “ducted mode” the top duct covers may be turned upside-down to hide the louver holes. 11. Assemble top duct covers together using (3) M3 x 6 screws on each side. (FIG. G, #2).
Installation – Ductless Recirculating www.zephyronline.com Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
Display (speed level, delay off, filter clean/change,clean air) clean mesh filter clean air replace charcoal filter Adjust 6 Speed Levels Lights On/Dim/Off 1 Power / Delay Off Button Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
Features & Controls – User Interface www.zephyronline.com Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “clean mesh filter” will illuminate indicating it is time to clean the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “clean mesh filter” will turn off and the 30 hour timer will reset.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR MILANO ISLAND Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3.
ZML-M90BG/M90BS ZML-E42BG/E42BS Voltage 120V 60Hz Power consumption Total: Max. 215W @ 3.5A Lamp: Max. 3Wx4 Fan: Max. 203W THERMALLY PROTECTED U V W U V W 5A 250V AC-N ON/OFF DOWN UP AC-L LAMP Pressure (inAq) Blower fan curve AC input: 120V 60Hz Outlet diameter : 8" 2.8 2.7 2.6 2.5 2.4 2.3 2.2 2.1 2 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.
List of Materials www.zephyronline.com DESCRIPTION PART# Replacement Parts Light Bulb, LED 3W Z0B-0032 Aluminum Mesh Filter 50200043 Optional Accessories Recirculating Kit ZRC-00ML Replacement Charcoal Filter Z0F-C002 Duct Cover Extension (up to 12’ ceiling) Z1C-03ML Gray Glass Canopy 90cm ZMG-03GY Gray Glass Canopy 42” ZMG-04GY To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty