Hood User Manual
Features & Controls – User Interface
12
www.zephyronline.com
Mesh Filter Clean Indicator (always enabled)
 - After 30 hours of fan usage the Graphic and words “
clean mesh filter” will illuminate indicating it is time to clean
 the mesh filters. Graphic and words will remain illuminated until reset.
 - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “
clean mesh 
 filter
” will turn off and the 30 hour timer will reset.
Charcoal Filter Replace Indicator (disabled by default, must be enabled if recirculating hood)
 - To enable Charcoal Filter Replacement Function:
  - With hood off, hold Button and Button simultaneously for three seconds. The Graphic will illuminate for  
  three seconds indicating the Charcoal Filter Replacement Function is enabled.
 - To disable Charcoal Filter Replacement Function:
  - With hood off, hold Button and Button simultaneously for three seconds. The Graphic will be   
  illuminated then turn off indicating the Charcoal Filter Replacement Function is disabled.
 - After 120 hours of fan usage the Graphic and words “
replace charcoal filter
” will illuminate indicating it is time to 
 replace the charcoal filter. Graphic and words will remain illuminated until reset.
 - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “
replace 
 charcoal filter
” will turn off and the 120 hour timer will reset.
Clean Air Indicator
 - Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.
  - To enable Clean Air Function:
 - With hood off, hold the Button and Button simultaneously for three seconds. The Graphic and 
  words “
clean air” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan 
  will turn off and the 4 hour timer will begin.
 - Graphic will remain on when Clean Air Function is enabled, even if fan is not on.
  - To disable Clean Air Function:
 - With hood off, hold the Button and Button simultaneously for three seconds until Graphic 
  turns off.
 - When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10 
 minutes the fan will turn off and the 4 hour timer will reset.
 - If the user changes the fan speed while the Clean Air Function is in use, the words “
clean air” will turn off but the Graphic 
 will remain illuminated. If the user presses the Button at any time the 4 hour clean air timer will reset.