Lights On/Dim/Off
Display (speed level, delay off, filter clean/change)
Adjust 5 Speed Levels
Power / Delay Off
1 POWER / DELAY OFF BUTTON
 Power Button Function
 - Button will turn power on and off for entire hood (fan and lights).
 - Hood will remember the last speed and light level it was turned off at.
  (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button 
  again and the hood will turn back on at speed 4 and high lights level.)
  Delay Off Button Function
 - With the fan on press and hold the Button for two seconds. The fan will change to speed 1 and the 
 5 minute delay off timer will start. 
 + LEDs will illuminate and slowly blink in accordance with the time 
  remaining until the fan and lights automatically turn off.
 - Pressing Button while Delay Off Function is enabled will turn the hood off and cancel the Delay Off 
 Function.
 ACT Verification
 - Airflow Control Technology (ACT) allows the installer to set the maximum fan CFM to align with local 
 codes and regulations. 
  - To verify the maximum fan CFM:
   - With hood off, hold the Button for two seconds. If all five fan speed indicators illuminate = 
   default maximum CFM. If four fan speed indicators illuminate = 390 maximum CFM. If 3 fan 
   speed indicators illuminate = 290 maximum CFM.
2 SPEED SELECTION BUTTON
 Fan Speed Decrease Button
 - Press this button to decrease fan speed. 5, 4, 3, 2, 1.
 - If fan is On Speed 1 and this button is pressed, fan will power Off.
  Fan Speed Increase Button
 - Press this button to increase fan speed. Fan On, 1, 2, 3, 4, 5.
 - If hood is Off and this button is pressed, fan will turn On Speed 1. 
 Act Enabled Speed Selections
 - When ACT is enabled, the number of fan speeds will be reduced as follows:
  - 390 CFM = Maximum 4 speeds
  - 290 CFM = Maximum 3 speeds
Lighted Glass Button
5
MODEL ZLC ONLY
Features & Controls - ICON Touch Controls