Use and Care Manual
13
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and ltered by a set of optional charcoal lters. The air is then puried and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most eective and ecient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal lters are required on top of its standard Metal 
Filter set. Order according to its part number below. The standard mesh lters are intended to capture residue 
from cooking and the optional charcoal lters help to purify fumes exhausted from cooking for recirculation. 
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED) 
Kit includes charcoal lters, charcoal lter brackets and air diverter plate.
Hood Models   Part No.   Filters in pkg.  
ZAN   ZRC-01AN      2       
ZSA   ZRC-00SV      2       
ZRV   ZRC-00RV      2       
ZRO   ZRC-01RO      2   
1. Purchase recirculating kit per the part number above
2.  Secure air diverter plate to wall below duct cover bracket. Run 6” 
ducting from top of hood and secure to air diverter plate. (FIG. B)
3.  ZAN: Remove aluminum mesh lters from hood. Secure charcoal lters 
to back side of aluminum mesh lter by 3 brackets. (FIG. B.2)
4.  ZSA, ZRV, ZRO: Remove aluminum mesh lters from hood. Secure 
charcoal lter brackets to the hood body behind each mesh lters using 
the screws included in the recirculating kit. Clip charcoal lters onto 
each charcoal lter bracket. (FIG. B.1)
5. Re-Install mesh lters. For more details refer to manual included 
with recirculating kit.
6.  Charcoal lters must be replaced after every 120 hours of use (or 
approximately every 3 to 4 months based on an average of 1 - 2 hrs. of 
daily cooking time).
Charcoal Filter Replacements
Hood Model    Part No.   Qty to Order 
ZAN    Z0F-C091   2   
ZSA / ZRV / ZRO  Z0F-C002   2   
DO NOT WASH CHARCOAL FILTERS. Charcoal lters may need 
to be changed more often depending on cooking habits.
Installation – Ductless Recirculating
B.1
B.2
FIG. B