Use, Care, and Installation Guide www.zephyronline.com Venezia ZVE-E30AS ZVE-E36AS ZVE-E42AS Model number: Serial Number: JUL08.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Hood Speci cations ................................................... Mounting the Range Hood ...................................... Ductless Recirculating .............................................. 5 6 7 8 9 10 FEATURES & CONTROLS Touch Controls ...........................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect. 90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect. 45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 28”. min. ducted min. recirc. max. min. 28” max. 36” Maximum mount height should be no higher than 36”. 32-1/2” 36“ 51” It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and re hazard; while hoods mounted too high will be hard to reach and will loose its performance and ef ciency. min.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certi ed Silver Tape or Duct Tape.
Front of Hood Side of Hood 14-5/16” 10” 1-5/8” 21-1/4” 10-5/8” 29-15/16”, 35-15/16”, 41-15/16” 24” 2” ø5 7/ 8” 8 electrical k/o 1-1/4” Top of Hood 4” Installation – Hood Specifications www.zephyronline.com min. ducted 32-1/2”” min. recirc. 36” max.
C/L 1. Measure from range top to hood bottom and mark line A. (28” minimum from range top) . Duct Cover Bracket 2. Plum and mark center line. 9-7/16" 3. Mark mounting height line B. (10-3/8” from line A) B 4. Mark mounting spread from C/L on line B. (9-7/16”) 5. Fasten (2) M4x1-1/4” screws into studs on line B. Do not fasten screws all the way. note: wood blocking may need to be added behind the drywall if no studs are present.
Installation – Ductless Recirculating www.zephyronline.com Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and ltered by a set of optional charcoal lters. The air is then puri ed and recirculated back within the home.
Features & Controls - Touch Controls Blower On/Off Display (speed level, delay off, filter clean/change) Lights On/Dim/Off Adjust 6 Speed Levels 15 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by pressing selected. to decrease and to increase speed levels. The display indicates levels 3.
Features & Controls – Charcoal Filter Change Reminder www.zephyronline.com Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to be replaced after every 120 hours of use. The charcoal filters should never be cleaned or placed in a dish washer.
Metal Filter Clean Indicator When A flashes on display, the metal filters installed are required to be cleaned. This will occur after every 30 hours of use. Clean Filters display < A > flashes A Re-setting Function Reset the filter clean reminder timer when filters are cleaned and re-installed (with hood off). Press and hold for approximately 5 seconds, the display will appear; hold for approximately 5 seconds until A on display disappears .
Maintenance – Cleaning and Metal Mesh Filter Care www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are dif cult to turn due to prolonged use, rmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR VENEZIA Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3.
PART# Replacement Parts Light Bulb MR16 (GU10) 50W (each) Metal Mesh Filter (each) Z0B0020S 50200004 Optional Accessories Recirculating Kit, ZVE-E30AS Recirculating Kit, ZVE-E36AS/E42AS Replacement Charcoal Filter (each) Duct Cover Extension Kit ZRC-0050 ZRC-0051 Z0F-C002 Z1C-00VE To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Two Year Limited Warranty f