Installation guide

9
 0HDVXUHIURPUDQJHWRSWRKRRGERWWRPDQGPDUNOLQH$´
PLQLPXPIURPUDQJHWRS
2. Plum and mark center line.
 0DUNPRXQWLQJKHLJKWOLQH%´IURPOLQH$
 0DUNPRXQWLQJVSUHDGIURP&/´
 )DVWHQ0[´VFUHZVLQWRVWXGVRQOLQH%EXWGRQRW
tighten all the way. Note: Wood blocking may need to be
added behind the drywall if no studs are present. Wall
anchors may also be used but check local codes for
compliance. Failure to use suitable wall anchors and
screws to hold the weight of the hood could result in
personal injury or damage to cooking surface or counter.
5HPRYHVFUHZVVHFXULQJHOHFWULFDOMXQFWLRQER[WRPRWRU
housing. Remove junction box.
 5HPRYHWKHDOXPLQXPPHVK¿OWHU
9. Hang hood onto the mounting screws and hand tighten each
VFUHZ),*$6HFXUHWKLUG0[´VFUHZWKURXJKLQVLGH
RIKRRGLQWRZDOOIRUH[WUDVXSSRUW),*$
10. Center and attach duct cover mounting bracket to wall just
EHORZWKHFHLOLQJRUVRI¿WXVLQJ0[´VFUHZV
11. Install electrical and duct work. Seal duct work with aluminum
duct tape. Re-install electrical junction box with cable lock and
LQVWDOOWKHHOHFWULFDO),*%
12. Power up hood and check for leaks around duct tape.
3ODFHWHOHVFRSLFGXFWFRYHUVRQWRKRRGDQGH[WHQGLQQHUWRS
GXFWFRYHUXSZDUGVDQGVHFXUHWRGXFWFRYHUEUDFNHWXVLQJ
M3.5 x 8 screws.
14. Place canopy over hood body and secure it to hood body using
[VFUHZVWKURXJK¿OWHURSHQLQJ
5HLQVWDOODOXPLQXPPHVK¿OWHU
* If using hood in recirculating mode you must secure the air diverter
plate onto wall before installing duct work and duct covers. Turn
to page 10 for more details.
8 15/16”
15 7/8”
Brackets are
pre-installed
2
26” min
1
CAUTION: At least two installers are
required
due to the weight and size of the
hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Installation – Mounting the Hood
Cable Lock
Cable Lock
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKW
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
FIG. A