E page 2 F page 22 S page 43 APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
Important safety Notice ..................................................................... 4 Electrical & Installation requirements ............................................. 5 Electrical requirements .............................................................. 5 Before installing the hood ........................................................... 5 List of Materials ................................................................................. 6 Parts supplied: .................................
Important safety Notice READ AND SAVE THESE INSTRUCTIONS CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.
ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: • To contact a qualified electrical installer. • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
List of Materials PARTS SUPPLIED: • • • • • Blower unit housing Hood canopy Metal filter x 1 Halogen light bulb x 2 Hardware Packet: Transition Allen spanner x 1 Lower bracket x 2 Upper Bracket x 2 Use, Care and Installation guide Template Cloth 2,9x9,5 screws x 2 (to fix the transition) 4,5x16 screws x 4 (2 to fix the drawer to the bottom of the cabinet + 2 to fix the deflector on top of the cabinet ceiling) 5x18 screws x 4 (upper/lower brackets adjusting screws) 3,5x9,5 x 4 (for definitive fixing of upp
Ductless (recirculating) version 7" 7" 3/8 Cut out for venting system and conduit 1" 1/4 7" 1/16 13/16" 13/16" 9" 1/4 23" 5/16 10" 1" 1/4 3" 3/8 21" 3/4 Cut out for blower unit housing passage 9" 1/16 21" 9"9" 13/16 13/16 2" 3/4 30"-36" 15/16" - 1" 3/4 7 Dimensions and clearances www.zephyronline.
Installation Instructions Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version). Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless (recirculating) version.
Duct pieces Equivalent number lenght x used = Duct pieces Equivalent number lenght x used = Total Total 3 1/4 ” x 10” Rect., straight 1 Ft. x( )= Ft. 6" Round wall cap with damper 30 Ft. x ( )= Ft. 6 ” Round,, straight 1 Ft. x( )= Ft. 6” Round, roof cap 30 Ft. x ( )= Ft. 7", 8” Round,, straight 1 Ft. x( )= Ft. 6” Round to 3 1/4 ” x 10” rect. transition 1 Ft. x( )= Ft. 3 1/4 ” x 10” Rect.90° elbow 15 Ft. x ( )= Ft. 16 Ft. x ( )= Ft. 3 1/4 ” x 10” Rect.45° elbow 9 Ft.
Installation box. Run wires through hole according the National Electrical Code or CSA Standards and local codes and ordinances. 1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit. Cover that surface with a protective covering and place all canopy hood parts and hardware in it.
8. Fit the blower unit housing inside the cabinet through the bottom opening. Check that fixing springs goes over the bottom panel.. Bottom opening Bottom panel Side fixing screws Upper + lower bracket definitive fixing screws Fixing springs .......apply the two bigger brackets (lower brackets) under the first two and.... 9. Apply two brackets (one per side) to the blower unit housing......... Upper bracket Lower bracket .......
Installation ..... tighten securely the two screws on upper brackets, check that blower housing is now well blocked, then, from the inside of the hood, fix definitively the lower brackets with one screw each. 10. Refinish the installation to cabinet with two fixing screws. Adjusting screws Final fixing screw Final fixing screw For Ductless (recirculating) installations Cabinet without ceiling ONLY: Install the deflector (available as an extra kit) on the transition - snap into place.
www.zephyronline.com 13. For Ductless (recirculating) installations Install one charcoal filter (available as an extra kit). 12. Electrical connection WARNING Electrical Shock Hazard Warning: Turn off power circuit at the service panel before wiring this unit. 120 VAC, 15 or 20 Amp circuit required. 14. Check all light bulbs to make sure they are secure in their sockets. Turn power on in service panel. Check lights and blower operation. 15. Install filter.
Description of the hood 1 2 3 4 5 6 Control panel Grease filter Grease filter release handle Halogen lamp (position and nr.
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking. Description of control panel: A A B C - D - E F - E B CD F Lighting: dim lighting / full lighting /off (loop control) - Works even with hood in stand by and/or drawer closed.
Maintenance CLEANING The cooker hood should be cleaned regularly internally and externally. For cleaning use the supplied cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks. Therefore we recommend observing these instructions.
Issue After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly. Metal filter is vibrating. Cause What to do 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3.
Warranty TO OBTAIN SERVICE UNDER WARRANTY: or any Service Related Questions, please call: 1-888-880-8368 Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.
Part Description Part# halogen bulb, 12V 20 W Z0B-0013 metal filter GF02ZA Part Description Part# Ductless Recirculating Kit ZRC-00GL charcoal replacement filter Z0F-C063 remote control 19 List of Part and Accessories www.zephyronline.