Hood User Manual
 The following instructions are for installing the internal blower.
CAUTION: To reduce the risk of fire and electric shock, install this rangehood 
only with internal blower models CBI-290A or CBI-600A.
For external and in-line blower prepara-
tion please turn to page 15. 
1.Remove the 6” round metal knockout 
plate from the blower plate by using 
a flat head screwdriver. See.Fig.1
2. Remove the (6) screws securing the 
blower plate to the blower housing 
and remove blower plate. See. Fig.2
3. Install internal blower into blower 
plate and secure using (4) screws in-
cluded with the blower. See Fig.3
 4. Secure capacitor box connected to  
the provided cable to the blower  
plate using (2) screws included with 
the blower. See.Fig.4
5. Secure Green/Yellow ground wire 
connected to the cable to the provi-
ded capacitor to blower plate.Fig.5
6. Attach the 6 pin male molex connec-
tor from blower wire to the 6 pin fe-
male molex connector located inside 
the blower housing. See Fig.6 
Installation - Internal Blower
- 13 - 