Owner Manual
5. Install the flange and fix it to the blower 
plate with the (4) screws. Fig. 5
6. Put the top cover back on.
7. With the aid of a slotted screwdriver, bre-
ak the grommet of circular hole through 
which the wires pass. Fig. 6
8. Insert the female connector in the ter-
minal box already attached to the hood. 
Fig. 7A
Pass the wires of the remote motor throu-
gh the terminal box hole and connect 
them to the connector wires. Fig.7B
Note: Carry out the power supplly con-
nection in accordance with the national 
electric code, ANSI/NFPA 70-1999. 
Note1: A cable lock (not included) may be 
required by local codes. Please review 
local codes for more information.