Downdraft Recirculation Kit Installation Instructions
2
Model ZRC-00LF
INSTALLATION INSTRUCTIONS
CONTENTS
1 - Recirculation Box
1 - Recirculation Filter
1 - Decorative Grille
1 - Parts Bag (containing):
6 - #10 x .625” screws
4 - #8 x .375” screws
2 - #8 x 1” screws
PLAN THE INSTALLATION
1. Determine where recirculation box will exhaust through
cabinet.
• Front (toe space), Back, Side (Left or Right).
• 14½” x 15” opening in cabinet base is required for
recirculation box.
• 3½” x 14¼” opening is required for exhaust.
2. Determine location of recirculation box.
• Plan to align blower outlet with recirculation box inlet.
IMPORTANT - Installation Requirements
The blower can be installed in either of two ways:
(1) attached to the downdraft and stabilized with
mounting legs.
(2) installed remotely (not attached to the downdraft),
using mounting brackets and wood framing.
Purchase blower separately. (Includes mounting legs and
mounting brackets.)
A minimum 24-inch wide cabinet is recommended.
The 8-inch round blower outlet and 8-inch round
recirculation box inlet must align vertically. (See page 2.)
15”
14½”
DECORATIVE
GRILLE
FILTER
RECIRCULATION
BOX
3½” x 14¼”
EXHAUST OPENING
OPENING IN
CABINET BASE
EXHAUST THROUGH CABINET FRONT (TOE SPACE)
3. Determine what lengths of duct are required. (Purchase
duct separately.)
• A length of flexible or rigid 8” round duct is required to
connect blower exhaust to recirculation box inlet.
• A length of 3¼” x 14” duct may be required to connect
to exhaust of recirculation box and extend to decorative
grille location.