Troubleshooting
The hood is not 
venting out properly.
Using the wrong size of ducting. Change the ducting to at least 6” or 
higher for the internal blower and 8” or 
higher for the external blower.
The hood might be hanging to 
high from the cook top.
Adjust the distance between the cooktop 
and the bottom of the hood within 24” 
and 36” range.
The wind from the opened 
windows or opened doors in the 
surrounding area are aecting 
the ventilation of the hood.
Close all the windows and doors to 
eliminate the outside wind flow.
Blockage in the duct opening or 
ductwork.
Remove all the blocking from the duct 
work or duct opening.
There are too many turns within 
the ducting.
Limit number of turns and/or increase 
duct size.
Filter is vibrating. Filter is loose. Adjust or change the filter.
RF Remote control 
does not work.
Battery is dead. Replace battery with type A23 12v.
Poor communication with the 
hood.
Remote control must be within 15 ft of 
hood.
RF Remote lost communication 
with the hood.
Reset hood and remote by switching 
power o at the circuit breaker for 5 
minutes. Place remote on counter top 
near the hood and switch the circuit 
breaker back on.
Possible Problem Possible Cause Solutions