Use and Care Manual
Table Of Contents
13
Trapeze Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Internal Blower Preparation
2. Secure internal blower to internal
blower flange by (4) M4*16 screws
from internal blower hardware.
1. Remove internal blower flange
from motor housing by (6) screws.
3. Secure AC power wiring box to
internal blower flange by (2) M4*8
screws.
5. Connect 9 pin molex connector
from capacitor cable to 9 pin
molex connector from internal
blower.
4. Secure ground wire to underside
of internal blower flange by (1)
3/16*3/8 screw and (1) washer.
6. Re-install internal blower flange
to motor housing by (6) screws
previously removed from step 1.
8. Connect 6 pin molex connector
from capacitor cable to 6 pin
molex connector from control
box. Connect 2 pin plug from AC
power cable to 2 pin plug from
control box. Secure cables to
hood interior with zip ties and zip
tie holders.
7. Secure motor housing to hood
body by (12) M4*6 screws.
9. Secure capacitor box to internal
hood body by (2) M4*8 screws
and secure ground wire by (1)
3/16*3/8 screws.