Blower Specifications

*Add blower Watts and Amps to AC Power details from hood spec sheet to determin total power consumption.
**For Designer Collection and AK83 hoods you must transition from 10” to 8” ducting before duct passes through
ceiling. A 10” to 8” adapter is included with external and in-line blowers.
The exception to this is ALU-ExxBxX which uses a 10” round.
MODEL
CBI-290A
CBI-290B
CBI-600A
CBI-600B
PBI-1100A
PBD-1200A
CBE-1000**
PBN-1000A**
BLOWERS
CBE-1000
(external)
PBN-1000A
(in-line)
BLOWER TYPE
Single Internal
Single Internal
Single Internal
Single Internal
Dual Internal
Dual Internal
External
In-line
MAX WATTS*
77
77
320
320
640
660
640
700
MAX AMPS*
0.75
0.75
2.75
2.75
5.45
5.8
5.45
6.25
CFM
200 - 290
200 - 290
240 - 600
240 - 600
500 - 1,100
400 - 1,200
500 - 1,000
500 - 1,000
SONES
1.4 - 3
1.4 - 3
1.8 - 6
1.8 - 6
3.5 - 8
3.5 - 9
NA
NA
COMPATIBLE MODELS
Designer Collection
AK83
Designer Collection
AK83
AK83, ALU-ExxBxX
AK70xxBS, AK75xxBS
AK83, Designer Collection
AK83, Designer Collection
ZEPHYRONLINE.COM
B L OWE R
S P E C IFIC AT I ON S
Zephyr Ventilation | 2277 Harbor Bay Parkway, Alameda, CA 94502 | 888.880.VENT
OCT19.03 01
1
”
1
”
O
U
T
L
ET
DBI-600A Internal/In-line 340 3.0 200 - 600 N/A DLI-ExxAxX
PBD-1300A Dual Internal 490 8.0 350 - 1,300 1 - 8 AK76xxAS, AK77xxAS, ZRP-ExxAS
Outlet
DBI-600A
(internal/in-line)
Inlet
12-3/4”
5-1/8”
5”
12-3/4”
10-3/8”
11-5/8”
7-3/8”
11-5/8”
5-1/4”
14-5/8”
15-7/8”
20-3/8”
20-3/8”
21-7/8”
11-13/16”