Installation Instructions
Mounting Height, Clearance, & Ducting
36"
Min 20” - Max 36” (electric cooktops)
Min 24” - Max 36” (gas cooktops)
A minimum of 6” round or 3-1/4” x 10” rectangular duct must 
be used to maintain maximum air flow eciency.
Always use rigid type metal ducts only. Flexible ducts could 
restrict air flow by up to 50%.
Also use the ducting calculation sheet (on page 8) to 
compute total available duct run when using elbows, 
transitions and caps.
ALWAYS, when possible, reduce the number or transitions 
and turns. If long duct run is required, increase duct size.
If turns or transitions are required; install as far away from 
hood duct output and as far apart, between the two as 
possible.
Minimum mount height between range top to hood bottom 
should be no less than 20” for electric cook tops and 24” for 
gas cook tops.
Maximum mount height should be no higher than 36”.
It is important to install the hood at the proper mounting height. Hoods mounted too low could result 
in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its 
performance and eciency.
If available, also refer range manufacturer’s height clearance requirements and recommended hood 
mounting height above range. Always check your local codes for any dierences.
For shipment and installation damages:
 Ź Please fully inspect unit for damage before installation.
 Ź If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or 
replacement.
 Ź If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
 Ź If the unit is damaged by the installer (if other than the customer), repair of replacement must be 
made by arrangement between customer and installer.