Hood User Manual
12
Tornado Mini Use, Care, and Installation Guide
TORNADO MINI
INSERT
CORE
Installation Instructions
Electrical Supply
Electrical wiring must be done by qualified person(s) in 
accordance with all applicable codes and standards. Turn o 
electrical power at service entrance before wiring.
WARNING
For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not 
use extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and ordinances.
This appliance requires a 120V 60Hz electrical supply, and connected to an individual, properly 
grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring 
must be 2 wire w/ ground. Please also refer to the Electrical Diagram labeled on product.
Grounding
FIG. A
28” Max.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical 
short circuit, grounding reduces the risk of electric shock by 
providing an escape wire for the electric current. This appliance 
is equipped with a cord having a grounding wire with a 
grounding plug. The plug must be plugged into an outlet that is 
properly installed and grounded.
WARNING - Improper grounding can result in a risk of electric 
shock.
Consult a qualified electrician if the grounding instructions are 
not completely understood, or if doubt exists as to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install 
an outlet near the appliance.
Position the electrical outlet within the space covered by or above the decorative canopy housing as 
space permits and as to not interfere with the round duct. Make sure the outlet is no further than 28” 
from the top of the hood body. 