manual

12
www.zephyronline.com
Installation – Remote Blower Preparation
 3ODFH´URXQGDGDSWHURQWRSRISRZHUSDFN
DQGVHFXUHZLWK0[VFUHZV&RQQHFW´
URXQGGXFWZRUNWR´URXQGDGDSWHU
2. Install threaded end of remote blower wiring
through external blower wiring knock out (B)
located in junction box on top of power pack.
3. Place cap over threaded end of remote blower
wiring and secure by turning clockwise.
4. Connect 6 pin male connector from blower
wiring to 6 pin female connector in the power
SDFNSOXJLVORFDWHGLQVLGHWKHSRZHUSDFN
SURWUXGLQJIURPWKHZKLWHFRQWUROERDUGER[
NOTE: For instructions on installing remote blowers, please refer to the CBE-1000 or PBN-1000A
manuals included in the blower packaging and on our website: www.zephyronline.com
CBE-1000 / PBN-1000A: WIRING DIAGRAM
White (common)
Black (high)
Blue (med)
Red (low)
Green (ground)
Remote Blower
Wiring Box
(hood)
Junction Box
(Remote Blower)
B
B
A
A: Ground wire screw
location (inside)
5. Secure green ground wire from remote
blower wiring to ground screw located
inside the power pack