A minimum of 6” round or 3-1/4” x 10” rectangular
duct must be used to maintain maximum air ow
efciency for single blower and 8” round duct for
dual and remote blowers.
Always use rigid type metal ducts only. Flexible
ducts could restrict air ow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and re hazard; while hoods
mounted too high will be hard to reach and will
lose its performance and efciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.


8” round minimum (dual blower)

N/A


6” round minimum (single blower)
8” round minimum (dual and remote blowers)

N/A
Min 26" - Max 36"
36"