Use and Care Manual

16
Tornado II & Tornado III Use, Care, and Installation Guide
TORNADO II &
TORNADO III
INSERT
PRO
Installation Instructions
AK8300BSX Remote Blower Preparation
1. Place 10” round adapter on top
of insert and secure it with (4)
M4x8 screws. Connect 10” round
ductwork to 10” round adapter.
2. Install threaded end of remote
blower wiring through external
blower wiring knock out locked in
junction box on top of insert.
3. Place cap over threaded end of
remote blower wiring and secure
by turning clockwise. Connect 6
pin male connector from blower
wiring to 6 pin female connector
in the insert.
4. Secure green ground wire from
remote blower wiring to ground
screw located inside the insert.
CBE-1000 / PBN-1000A: WIRING DIAGRAM
White (common)
Black (high)
Blue (med)
Red (low)
Green (ground)
Remote Blower
Wiring Box
(hood)
Junction Box
(Remote Blower)
NOTE: For instructions on installing remote blowers, please refer to the CBE-1000 or PBN-1000A
manuals included in the blower packaging and on our website: www.zephyronline.com