WWW.ZEPHYRONLINE.COM Cypress AK7836CS, AK7842CS, AK7848CS, AK7854CS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA FEB22.
PRO CY P R ES S WA L L 2 Cypress Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information............................................................................. 4-6 Types of Safety Warnings.................................................................... 4 General Safety...................................................................................4-5 Operation............................................................................................ 6 Electrical Requirements.........................................................
PRO Safety Information CY P R ES S WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
PRO Safety Information CY P R ES S WA L L READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. ► The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
PRO Installation Instructions CY P R ES S WA L L Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 10” round duct is recommended to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps. n. mi . ” 30 max ” 36 ” 36 ALWAYS, when possible, reduce the number or transitions and turns.
PRO Installation Instructions CY P R ES S WA L L Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM Hood Specifications Side View Top View 2-5/8” 14-3/16” 10-3/8” 1-3/4” 4-5/16” 6-1/16” 11-9/16” 10-3/8” 15” 50.
PRO Installation Instructions CY P R ES S WA L L Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood 1. Select preferred ducting application (vertical or horizontal) and prepare hood. Refer to page 14 for horizontal ducting conversion. C/L C/L B B wood board wood board 2. Plum and mark center line on wall. 16-7/8” 16-7/8” 3. Choose desired height above cooking surface (30” min). Level and mark hood bottom, line A (FIG. B). A A min min 30” 30” 4. Level and mark top of wood board, line B (FIG. B) 16 7/8” from line A. 5.
PRO Installation Instructions CY P R ES S WA L L Horizontal Ducting Conversion This range hood is equipped with a 10" round vertical duct option by default. To convert from 10" round vertical to 10" round horizontal ducting, please follow the instructions below. 1. Disconnect blower plug. 2. Remove (4) screws from interior of hood body attaching blower plate to top of hood body. Remove blower and blower plate. A 14 3. Knock out plate A for dual blower horizontal ducting.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Conversion 4. From inside hood body, position top cover plate to top of hood body. From outside hood body, attach top cover plate to top of hood body using (4) 3/16 x 3/8 screws. 5. Position dual blower plate onto interior back wall mounting brackets inside hood body. Attach by (4) screws previously removed from step 2. Re-connect blower plug. 6. Attach 10 inch round blower collar to back of hood using (4) M4 x 8 screws.
PRO Features & Controls CY P R ES S WA L L Rotary Controls 1 Blower On/Off/Speed Selection OFF OFF 1 1 2 2 3 OFF 2 Lights Dim/Bright/Off 1 Blower On/Off/Speed Selection Rotate dial to change speed levels, (1) for low speed, (2) for medium speed and (3) for high speed. 2 Lights Dim/Bright/Off Rotate dial to change light settings, (1) for dim light and (2) for bright light.
Maintenance ZEPHYRONLINE.COM Hood & Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
PRO Maintenance CY P R ES S WA L L Removing Pro Baffle Filters, FIG. D 1. Push filter away from front of range hood using handles. 2. Pivot front of filter downward. 1 3. Remove filter by pulling away from hood. Replacing Pro Baffle Filters Hood Model Part Number AK7836CS 50210031 AK7842CS 50210031 AK7848CS 50210031 AK7854CS 50210031 2 Qty. to Order 2 2 3 3 3 FIG. D LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts.
Wiring Diagram ZEPHYRONLINE.
PRO Troubleshooting CY P R ES S WA L L Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause Solutions The power source is not turned ON. The power line and the cable locking connector is not connecting properly. The switch board wirings are disconnected. The switch board is defective. The blower wire is not connected. The thermally protected system detects if the blower is too hot to operate and shuts the blower down. Damaged capacitor.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood is not venting out properly. Filter is vibrating. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 30” and 36” range. Close all the windows and doors to eliminate the outside wind flow.
PRO List of Parts & Accessories CY P R ES S WA L L Description Replacement Parts LumiLight LED, 6W Pro Baffle Filter (each) Optional Accessories 12" Duct Cover (36") 12" Duct Cover (42") 12" Duct Cover (48") 12" Duct Cover (54") Duct Cover Extension (10' - 12' ceilings) Part Number Z0B0050 50210031 AK0736BS AK0742BS AK0748BS AK0754BS Z1C-0178 To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.COM Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
PRO Product Registration CY P R ES S WA L L Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Cypress AK7836CS, AK7842CS, AK7848CS, AK7854CS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DESTINÉ À L’EXTÉRIEUR PATIO COUVERT OU ZONE LANAI FEB22.
PRO CY P R ES S MUR 2 Cypress Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité........................................................................ 4-6 Types d’avertissements de sécurité...................................................... 4 Sécurité générale................................................................................4-5 Opération............................................................................................ 6 Exigences électriques.......................................................
PRO Consignes de sécurité CY P R ES S MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
PRO Consignes de sécurité CY P R ES S MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. ► Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
PRO Instructions d’installation CY P R ES S MUR Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Un conduit rond d’au moins 10 po est recommandé pour maintenir une efficacité maximale du débit d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
PRO Instructions d’installation CY P R ES S MUR Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. ► Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte Vue de côté Vue de dessus 2-5/8 po 14-3/16 po 10-3/8 po 1-3/4 po 4-5/16 po 6-1/16 po 11-9/16 po 10-3/8 po 15 po 50.
PRO Instructions d’installation CY P R ES S MUR Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte 1. Sélectionnez l’application de conduit préférée (verticale ou horizontale) et préparez la hotte. Reportez-vous à la page 14 pour la conversion des conduits horizontaux. C/L C/L B planche de bois B 4 po planche de bois 4 po 16-7/8 po 2. Prune et marque la ligne médiane sur le mur. 16-7/8 po A A 3. Choisissez la hauteur désirée au-dessus de la surface de cuisson (30 po min). Nivelez et marquez le bas de la hotte, ligne A (FIG. B).
PRO Instructions d’installation CY P R ES S MUR Conversion de conduits horizontaux Cette hotte est équipée par défaut d’une option de conduit vertical rond de 10”. Pour convertir un conduit vertical rond de 10” en conduit horizontal rond de 10”, veuillez suivre les instructions cidessous. 1. Débranchez la prise du ventilateur. 2. Retirez les (4) vis de l’intérieur du corps de la hotte fixant la plaque du ventilateur au haut du corps de la hotte. Retirez le ventilateur et la plaque du ventilateur.
Instructions d’installation ZEPHYRONLINE.COM Conversion de conduits horizontaux 4. Depuis l’intérieur du corps de la hotte, placez la plaque de couverture supérieure sur le dessus du corps de la hotte. Depuis l’extérieur du corps de la hotte, fixez la plaque de couverture supérieure au haut du corps de la hotte à l’aide de (4) vis 3/16 x 3/8. 5. Positionnez la plaque du ventilateur double sur les supports de montage du mur arrière intérieur à l’intérieur du corps de la hotte.
PRO Fonctionnalités et commandes CY P R ES S MUR Commandes rotatives 1 Ventilateur Marche/Arrêt/Sélection de vitesse OFF OFF 1 1 2 2 3 OFF 2 Lumières tamisées/lumineuses/éteintes 1 Ventilateur Marche/Arrêt/Sélection de vitesse Tournez le cadran pour changer les niveaux de vitesse, (1) pour une vitesse faible, (2) pour une vitesse moyenne et (3) pour une vitesse élevée.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. ► N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
PRO Entretien CY P R ES S MUR Retrait des filtres déflecteurs pro, FIG. E 1. Éloignez le filtre de l’avant de la hotte à l’aide des poignées. 2. Faites pivoter l’avant du filtre vers le bas. 1 3. Retirez le filtre en le tirant hors de la hotte. Remplacement des filtres déflecteurs pro Modèle de hotte Numéro d’article Qté. commander AK7836CS 50210031 2 AK7842CS 50210031 2 AK7848CS 50210031 3 AK7854CS 50210031 3 2 3 FIG.
Schéma de câblage ZEPHYRONLINE.
PRO Dépannage CY P R ES S MUR Problème possible Après l'installation, l'appareil ne fonctionne pas. Cause possible Solutions La source d'alimentation n'est pas allumée. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement. Les câblages du tableau de distribution sont déconnectés. Assurez-vous que le disjoncteur et l’appareil sont sous tension. Vérifiez que la connexion électrique avec l'appareil est correctement connectée.
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions La hotte ne s'échappe Utilisation de la mauvaise taille de Changer le conduit à la bonne taille. pas correctement. conduit. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la plaque de cuisson et le bas de la hotte dans les limites de 30 po et 36 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
PRO Liste des pièces et accessoires CY P R ES S MUR La description Pièces de rechange LumiLight LED, 6W Filtre déflecteur pro (chacun) Accessoires optionnels Couvercle de conduit de 12 po (36 po) Couvercle de conduit de 12 po (42 po) Couvercle de conduit de 12 po (48 po) Couvercle de conduit de 12 po (54 po) Rallonge de couvre-conduit (plafonds de 10’ à 12’) Numéro d’article Z0B0050 50210031 AK0736BS AK0742BS AK0748BS AK0754BS Z1C-0178 Pour commander des pièces, visitez-nous en ligne à http://store.
Garantie limitée ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
PRO Enregistrement du produit CY P R ES S MUR Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.