Installation Guide
11
1. Disconnect blower plug.
2. Remove(4)screwsfrominteriorofhoodbody
attaching blower plate to top of hood body.
Remove blower and blower plate.
3. KnockoutrearplateBforrearrectangularrear
ducting or plate C for 8 inch round rear ducting.
This range hood is equipped standard with a 10” round vertical duct option. To convert from 10” round vertical to
10” round horizontal ducting please following the instructions below.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
Installation – Horizontal Ducting Conversion
3. KnockoutplateAfordualblowerhorizontal
ducting.
A
4. From inside hood body, position top cover plate
to top of hood body. From outside hood body,
attach top cover plate to top of hood body using
(4)3/16x3/8screws.
5. Positiondualblowerplateontointeriorbackwall
mountingbracketsinsidehoodbody.Attachby
(4)screwspreviouslyremovedfromstep2.Re-
connect blower plug.
6. Attach10inchroundblowercollartobackof
hoodusing(4)M4x8screws.