Use, Care, and Installation Guide www.zephyronline.com Cypress AK7836BS AK7842BS AK7848BS AK7854BS INTENDED FOR OUTDOOR COVERED PATIO OR LANAI AREA. Model number: Serial Number: Date of Purchase: Sales Dealer: DEC15.0101 © 2015 Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... 6SHFL¿FDWLRQV ............................................................... Electrical ......................................................................... Mounting the Range Hood ...................................... Horizontal Ducting Conversion..............................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.com MODELS: AK7836BS, AK7842BS, AK7848BS, AK7854BS PARTS SUPPLIED 1 - Hood %DIÀH ¿OWHUV IRU $. %6 $.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 30”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG ¿UH KD]DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORVH LWV SHUIRUPDQFH DQG HI¿FLHQF\ If available, also refer range manufacturer’s height clearance requirements and rec
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only.
Installation – 6SHFL¿FDWLRQV www.zephyronline.com Side View Top View 2 5/8” 14 3/16” 10 3/8” 1 3/4” 4 5/16” 6 1/16” 11 9/16” 10 3/8” 15” 50.
WARNING $OO (OHFWULFDO ZRUN PXVW E\ SHUIRUPHG E\ TXDOL¿HG HOHFWULFLDQ RU SHUVRQ ZLWK VLPLODU WHFKQLFDO NQRZ how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Mounting the Range Hood www.zephyronline.com ! CAUTION: At least two installers are required due to the weight and size of the hood. C/L 6HOHFW SUHIHUUHG GXFWLQJ DSSOLFDWLRQ YHUWLFDO RU KRUL]RQWDO DQG prepare hood. Refer to page 11 for horizontal ducting conversion. 2. Plum and mark center line on wall. &KRRVH GHVLUHG KHLJKW DERYH FRRNLQJ VXUIDFH ´ PLQ /HYHO DQG PDUN KRRG ERWWRP OLQH $ ),* /HYHO DQG PDUN WRS RI ZRRG ERDUG OLQH % ),* ´ IURP line A.
VERTICAL TO HORIZONTAL DUCTING CONVERSION 5HPRYH VFUHZV IURP LQWHULRU RI KRRG ERG\ attaching blower plate to top of hood body. Remove blower and blower plate. 1. Disconnect blower plug. A 3. Knock out plate A for dual blower horizontal ducting. 4. From inside hood body, position top cover plate to top of hood body. From outside hood body, attach top cover plate to top of hood body using [ VFUHZV 5.
Features & Controls – Rotary Controls www.zephyronline.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless OXVWHU DQG JUDLQ $OZD\V VFUXE OLJKWO\ XVLQJ D PLFUR ¿EHU RU FOHDQ FRWWRQ FORWK DQG ZLWK JUDLQ 6WDLQOHVV 6WHHO %DIÀH )
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. ,I EXOEV DUH GLI¿FXOW WR WXUQ GXH WR SURORQJHG XVH ¿UPO\ DWWDFK D JODVV VXFWLRQ FXS DSSUR[LPDWHO\ WKH diameter of the bul
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch wirings are disconnected. 3. Make sure the wirings at the switch are connected properly. 4. The switch is defective. 4. Change the switch. 1.
Wiring Diagrams www.zephyronline.com MAX.HALOGEN LIGHT BULBS. USE ONLY TYPE MR16, GU10, 35 W. AK7836BS / AK7842BS VOLTS HZ MAX AMPS 120 60 9 CIRCUIT DIAGRAM B 34 B 34 2 A USE ONLY TYPE MR16, GU10, 35 W. 2 A MAX.HALOGEN LIGHT BULBS.
17 Fan Curve Diagrams
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART # Replacement Parts /LJKW %XOE 05 *8 : HDFK %DIÀH )LOWHU ´ ´ HDFK %DIÀH )LOWHU ´ ´ HDFK = % Optional Accessories ´ 'XFW &RYHU ´ 'XFW &RYHU ´ 'XFW &RYHU ´ 'XFW &RYHU ´ ´ ´ ´ $. %6 $. %6 $. %6 $. %6 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide,
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. 20 | Alameda, CA 94502 | 1.888.880.