Use and Care Manual

13
5. KnockoutplateAfordualblowerhorizontal
ducting.
6. Position dual blower inside hood body. Attach by
(4)screwspreviouslyremovedfromstep2.
7. From inside hood body, position top cover plate
to top of hood body. From outisde hood body,
attach top cover plate to top of hood body using
(4)3/16x3/8screws.
8. Attach10inchroundblowercollartobackof
hoodusing(4)M4x8screws.Connectblower
wire extension cable to new blower and connect
both plugs from each blower to female plugs
behind switch panel.
A
Installation – PBD-1300A Dual Blower Horizontal Ducting
Follow Steps 1 through 4 on page 13, then continue PBD-1300A horiztantal ducting installation by following the
steps below.
7. Attach dual blower PCB box to electronics
bracketby(4)screws.
8. Connect single and dual blower PCB blower
plugandwhiteandblackpowercables.