Specifications

jul14.0201 Zephyr Ventilation | 2277 Harbor Bay Parkway Alameda, CA 94502 | 888.880.VENT | zephyronline.com
europa power breeze
tempest ii wall | pro-style
*When ACT™ is enabled the maximum speed levels will change. ACT 390 CFM = 3 speeds and ACT 290 CFM = 2 speeds.
**Recirculating kit includes a return-air box which adds an additional 4" to the hood height. Recirculating kit is only compatible with single blower.
If horizontally ducting via 3-1/4" x 10", the maximum airflow of 650 CFM will be reduced to 550 CFM.
††Mounting height refers to distance between top of cooking surface and bottom of hood.
Specifications subject to change, check zephyronline.com for up-to-date information.
size
AK7500Bs
AK7536Bs
AK7548Bs
30”
36”
48"
PeRFORMANCe
(INCLUDED) SINGLE INTERNAL BLOWER CFM 200 - 650
MIN.-MAX. SONES 1 - 6
(OPTIONAL) DUAL INTERNAL BLOWER CFM 400 - 1,200
MIN.-MAX. SONES 2 - 9
COlOR
STAINLESS STEEL SS
FeAtuRes
CONTROLS Electronic Touch
SPEED LEVELS 6*
AUTO DELAY-OFF Yes
CLEAN AIR MODE Yes
LIGHTING
AK7500Bs/AK7536Bs
AK7548Bs
Halogen, 35W x 2
Halogen, 35W x 4
DUAL LEVEL LIGHTING Yes
FILTERS
AK7500Bs
AK7536Bs
AK7548Bs
SS Pro-Bae x 2
SS Pro-Bae x 3
SS Pro-Bae x 4
WIRELESS REMOTE CONTROL OPTION Yes
DUAL INTERNAL BLOWER OPTION Yes
RECIRCULATING OPTION**
AK7500Bs/AK7536Bs
AK7548Bs
Yes, Single Blower Only
NA
duCt sPeCiFiCAtiONs
SINGLE INTERNAL BLOWER - VERTICAL 8” Round
SINGLE INTERNAL BLOWER - HORIZONTAL 3-1/4" x 10" or 8" Round
DUAL INTERNAL BLOWER - VERTICAL 10" Round
DUAL INTERNAL BLOWER - HORIZONTAL 10” Round
AC POweR
SINGLE INTERNAL BLOWER
DUAL INTERNAL BLOWER
120V, 60Hz at Max. 5A
120V, 60Hz at Max. 9A
OPtiONAl ACCessORies
12” DUCT COVER
AK7500Bs
AK7536Bs
AK7548Bs
AK0720
AK0726
AK0728
WIRELESS REMOTE CONTROL 14000005
DUAL INTERNAL BLOWER KIT PBD-1200A
RECIRCULATING KIT**
AK7500Bs
AK7536Bs
AK7548Bs
ZRC-7000B
ZRC-7036B
NA
BACKSPLASH WITH SHELVES
AK7500Bs
AK7536Bs
AK7548Bs
AK0710
AK0716
AK0712
MAKE-UP AIR KIT, SINGLE BLOWER MUA008A
MAKE-UP AIR KIT, DUAL BLOWER MUA010A
MOuNtiNg height†† 26” - 36”
wARR ANtY 3 Years Parts, 1 Year Labor
BACK
TOP
SIDE
* Single Blower Rect. Ducting Dimension
** Single Blower Round Ducting Dimension
*** Dual Blower Dimension
8 9/16”
1 3/4”
1 1/16”
11 9/16”
6”
**7 7/8”
or
***10 3/8”
**9 1/2”or ***14 3/16”
2 3/4”
**7 7/8”
or
***9 15/16”
R 9/16”
29 7/8” (30”), 35 7/8” (36”), 47 7/8” (48”)
C/L
12”
24”
4”
18”
**7 7/8” or ***10 3/8”
**1 15/16”
or
***4 5/16”
11 9/16”
10 3/4”
*3 3/16”
**7 7/8”
***10 3/8”
*9 7/8”, **9 1/2”, **14 3/16”
**7 7/8” or ***9 15/16”
1 11/16”
C/L