Use And Care Manual / Installation Guide
Troubleshooting
21
TROUBLESHOOTING PROCEDURES FOR TEMPEST II
Issue Cause What to do
After installation,
the unit doesn’t
ZRUN
1. The power source is not turned ON. 0DNHVXUHWKHFLUFXLWEUHDNHUDQGWKHXQLW¶V
power is ON.
7KHSRZHUOLQHDQGWKHFDEOHORFNLQJFRQQHFWRU
is not connecting properly.
&KHFNWKHSRZHUFRQQHFWLRQZLWKWKHXQLWLV
connected properly.
3. The switch board and control board wirings are
disconnected.
0DNHVXUHWKHZLULQJVEHWZHHQWKHVZLWFK
board and control board are connected
properly.
4. The wires on control board are loose. 0DNHVXUHWKHZLUHVRQWKHFRQWUROERDUGDUH
connected properly.
5. The switch board or control board is defective. 5. Change the switch board or control board.
/LJKWZRUNVEXW
the blower is not
turning.
1. The blower is defective, possible seized. 1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The blower wire is not connected. 0DNHVXUHWKHEORZHUZLUHLVSOXJJHGLQWRWKH
molex connector.
The unit is
vibrating.
1. The blower is not secure in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Change the blower.
3. The hood is not secured in place. &KHFNWKHLQVWDOODWLRQRIWKHKRRG
The blower is
ZRUNLQJEXWWKH
lights are not.
1. Defective halogen bulb. 1. Change the halogen bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
3. The light bulb plug is disconnected. &KHFNWKHOLJKWEXOESOXJFRQQHFWLRQ
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
FRRNWRS
$GMXVWWKHGLVWDQFHEHWZHHQWKHFRRNWRSDQG
the bottom of the hood within 26” and 36”
range.
2. The wind from the opened windows or opened
GRRUVLQWKHVXUURXQGLQJDUHDDUHDႇHFWLQJWKH
ventilation of the hood.
2. Close all the windows and doors to eliminate
WKHRXWVLGHZLQGÀRZ
%ORFNDJHLQWKHGXFWRSHQLQJRUGXFWZRUN 5HPRYHDOOWKHEORFNLQJIURPWKHGXFWZRUNRU
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
0HWDO¿OWHULV
vibrating.
0HWDO¿OWHULVORRVH &KDQJHWKHPHWDO¿OWHU
6SULQJFOLSLVEURNHQ 2. Change the spring clip.
The blower turns
on by itself.
1. The clean air function has been enabled turning
the blower on every 4 hours.
1. Disable the clean air function by following the
steps on page 17.