WWW.ZEPHYRONLINE.COM Tidal I AK7300AS, AK7336AS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology DEC20.
PRO TIDAL I UNDER-CABINET 2 Tidal I Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
PRO Safety Information TIDAL I UNDER-CABINET READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
PRO Safety Information TIDAL I UNDER-CABINET READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.COM Parts Supplied Quantity 1 2 2 1 1 1 1 1 Part Hood Pro baffle filters LumiLight LED, 6W (pre-installed) 8” round transition collar 3-1/4” x 10” rectangular collar with damper Single blower motor (pre-installed) Top cover plate (for horizontal ducting) Hardware package #6 x 2” (4) #6 x 1-1/2” (4) #6 x 1” (4) M3.
PRO Installation Instructions TIDAL I UNDER-CABINET Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting in. m .
PRO Installation Instructions TIDAL I UNDER-CABINET Mounting Height, Clearance, & Ducting A minimum of 8” round duct or 3-1/4” x 10” rectangular duct is recommended to maintain maximum air flow efficiency for single blower and 10” round duct for dual internal blower. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 11) to compute total available duct run when using elbows, transitions and caps.
Installation Instructions ZEPHYRONLINE.COM Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
PRO Installation Instructions TIDAL I UNDER-CABINET Ů Top 1-15/16” 1-11/16” 27-7/8” or 33-7/8” *8-1/16” **10-3/8” 8-9/16” 6” 7-7/8” * 8” round ducting ** 10” round ducting *** Rectangular ducting *9-1/2” **14-3/16” 1-15/16” 9-7/8” 7-3/8” 1-1/4” 3-3/16” 4-1/8” or 4-9/16” 11/16” Back 26” or 31-9/16” 29-7/8” or 35-7/8” Side *14-1/16” ***13-1/2” *12-15/16” **15-5/16” * 8” round ducting ** 10” round ducting *** Rectangular ducting 3” 11” 12” 22-1/2” 12 Tidal I Use, Ca
Installation Instructions ZEPHYRONLINE.COM Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
PRO Installation Instructions TIDAL I UNDER-CABINET Horizontal Ducting Conversion By default the Tidal I is pre-configured for 8” round vertical ducting. These steps are for 8” round and 3-1/4”x10” rectangular horizontal ducting. If you are continuing with vertical ducting, please skip these steps. NOTE: Horizontal ducting is only available for the single internal blower. 1. Disconnect blower plug. 2. Remove (4) screws at top of hood body attaching blower to blower plate.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Conversion A B 4. Knock out rear plates B for 8” round rear ducting or plate A only for 3-1/4” x 10” rectangular rear ducting. 5. Place blower inside hood as shown. 6. Attach blower to hood body from the back of hood using (4) previously removed blower screws and reconnect blower plug.
PRO Installation Instructions TIDAL I UNDER-CABINET Horizontal Ducting Conversion 7. Attach 8” round duct collar or 3 1/4” x 10” rectangular duct collar to back of hood body using (4) M3.5 x 8 screws. 8. From inside hood body, position top cover plate to top of hood body. From outside hood body, attach top cover plate to top of hood body using (4) 3/16” x 3/8” screws.
Installation Instructions ZEPHYRONLINE.COM PBD-1300B Dual Blower Installation This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. PBD-1300B dual blower kit compatible only with AK7336AS. 1. Remove the baffle filters and if applicable, remove the side panels. Disconnect blower plug. 2. Remove (4) screws at top of hood body attaching blower to blower plate.
PRO Installation Instructions TIDAL I UNDER-CABINET PBD-1300B Dual Blower Installation 5. Install previously removed blower onto one side of dual blower plate and attach by (4) previously removed screws from step 2. 6. Install blower from PBD-1300B kit onto other side of dual blower plate by (4) 3/16 x 3/8 screws. 7. Dual blower screw mount locations. 8. Remove (4) screws to remove the light panel. Install dual blower PCB inside the hood body.
Installation Instructions ZEPHYRONLINE.COM PBD-1300B Dual Blower Installation 9. Refer to page 32 section for this step. Connect the wiring from the dual blower including both blower plugs, blower cable 6 pin connector (E), dual blower switch cable (H), black single pin power cord from dual blower (K), and white single pin power cord (F) to dual blower PCB. 10. Place 10” round adapter (included with PBD-1300B) on top of hood and secure with (4) M3.5 x 8 screws.
PRO Installation Instructions TIDAL I UNDER-CABINET Mounting the Hood If recirculating range hood refer to the manual included with ZRC-70xxC recirculating kit or on our website prior to installing hood. Hood is designed for installation under a kitchen cabinet. Electrical 1. Prepare duct location on hood (vertical or horizontal). Duct opening/ cutout 2. Begin installation by removing the safety screw on top of hood body and filters. Then remove side panels by (2) screws. Aluminum duct tape 3.
Features & Controls ZEPHYRONLINE.COM Proximity Controls Power Lights Display & Icons Adjust 6 Speed Levels PROXIMITY SENSOR Ź When approaching the hood while it is powered off, the Power, Fan Decrease, Fan Increase, and Light icons will illuminate, and “HELLO” will appear on the LCD display for 2 seconds. Ź If neither the fan nor lights are turned on within 60 seconds, the icons will turn off, and “GOODBYE” will appear on the LCD display for 2 seconds.
PRO Features & Controls TIDAL I UNDER-CABINET Proximity Controls DISPLAY ICONS & FUNCTIONS Ů Ź The notification bell icon will illuminate when an action needs to be taken. Tapping the icon will cycle through the notifications. The notification bell will remain illuminated until all notifications are resolved. The notification bell will not illuminate when the hood and controls are powered off.
Features & Controls ZEPHYRONLINE.COM Proximity Controls Ļ Ů Ź Airflow Control Technology (ACT™) allows the installer to set the maximum fan CFM to align with local codes and regulations. When the fan is off, press and hold for 3 seconds to display ACT™ status. Ź ACT 290 = 3 speeds, ACT 390 = 4 speeds, ACT 590 = 5 speeds. Grease Filter Clean Reminder Ź After 60 hours of fan use, the notification bell icon will illuminate.
PRO Features & Controls TIDAL I UNDER-CABINET Zephyr Connect Your range hood is compatible with our Zephyr Connect app. All you need is a WiFi connection with access to the Internet that can reach the location of your range hood. Zephyr Connect allows you to control your range hood from anywhere using a mobile device or your Amazon Alexa or Google Home smart speaker. Zephyr Connect also includes real time diagnostics and provides you with important product information.
Features & Controls ZEPHYRONLINE.
PRO Features & Controls TIDAL I UNDER-CABINET Optional RF Remote Control To order the RF remote control, the part number is 14000005. The blue antenna wire needs to be extended for optimal signal. Please refer to section, Mounting the Hood, for instructions. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Features & Controls ZEPHYRONLINE.COM Optional RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. C. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the liner. FIG.
PRO Maintenance TIDAL I UNDER-CABINET Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Maintenance ZEPHYRONLINE.COM Ų ĕ Ę 1. Push filter toward front of range hood using handles. 2. Pivot back of filter downward. 1 3. Remove filter by pulling away from hood. Ų Hood Model AK7300AS AK7336AS Part Number 50210039 50210039 2 Qty. to Order 2 2 Recirculating Kit Ĭ Ů ĭ Hood Model Part Number Qty.
PRO Maintenance TIDAL I UNDER-CABINET LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. Ĭ Ę ĭė 1. Remove pro baffle filters. 2. (If applicable) Remove both spacer panels by 2 screws for each spacer panel. 3. Remove light panel by 4 screws. 4. Disconnect LED light quick connector. 5. Push in the two side clips on the ends of the LED light.
ACT™ Conversion ZEPHYRONLINE.COM ů Ĭ Ļĭ Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of three most commonly specified CFM levels; 590, 390, or 290 CFM. The usage of ACT™ may not be necessary for your installation.
PRO ACT™ Conversion TIDAL I UNDER-CABINET Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. J. 2. Change plastic jumper positioning as shown in FIG. K to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
ACT™ Conversion ZEPHYRONLINE.COM Enabling ACT™ 1. PC board located behind the light panel. 2. (If applicable) Remove both spacer panels by 2 screws for each spacer panel. 3. Remove 4 screws attaching light panel. FIG. J Jumper Pins 2 4 6 8 Plastic Jumper 1 3 5 7 Jumper 7-8 DEFAULT POSITION 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 1 3 5 7 PC Board 1 3 5 7 1 3 5 7 1 3 5 7 Jumper 5-6 Max. Blower CFM 590 Jumper 3-4 Max. Blower CFM 390 Jumper 1-2 Max. Blower CFM 290 FIG.
PRO Wiring Diagram TIDAL I Wiring Diagram White Black Green UNDER-CABINET Body Black Black Red Motor Single Blower Body White Black Green White LED LED ANT WIFI MOTOR-2 WHITE WHITE WIFI MOTOR-1 K WHITE WHITE BLACK WHITE BLACK BLACK BLACK B/W WHITE BLACK BLACK B/W Dual Blower A. Wi-Fi connection wire C. Power wire for expansion PCB D. Power wire for expansion PCB E. Blower connection wire F. Blower connection wire G. Control connection wire H.
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause Solutions The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
PRO Troubleshooting TIDAL I UNDER-CABINET Possible Problem The hood is not venting out properly. The unit turns on by itself. Filter is vibrating. RF Remote control does not work. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 24” and 34” range. Close all the windows and doors to eliminate the outside wind flow.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The range hood won’t connect to Wi-Fi. User cannot change Wi-Fi connections. Cannot bind the hood to my Zephyr Connect account. Zephyr Connect app won’t register user inputs. Zephyr Connect app stuck on “Loading”. Possible Cause The user’s router or modem is turned off. The user’s router is connected to a 5 GHz wireless frequency. The user’s coaxial cables are loose. Solutions Turn on the router or modem. Connect to the 2.
PRO List of Parts & Accessories TIDAL I UNDER-CABINET Description Replacement Parts LumiLight LED, 6W Pro Baffle Filter (each) Optional Accessories Dual Internal Blower Make-up Air Kit (Single Blower) Make-up Air Kit (Dual Blower) RF Remote Control Duct Cover 30” x 12” Duct Cover 36” x 12” Duct Cover 30” x 24” Duct Cover 36” x 24” Part Number Z0B0048 50210039 PBD-1300B MUA008A MUA010A 14000005 AK0720 AK0726 AK1720 AK1726 To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.
PRO Product Registration TIDAL I UNDER-CABINET Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Tidal I AK7300AS, AK7336AS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology DEC20.
PRO TIDAL I S O U S -A R M O I R E 2 Tidal I Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
PRO Consignes de sécurité TIDAL I S O U S -A R M O I R E LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
Consignes de sécurité ZEPHYRONLINE.
PRO Consignes de sécurité TIDAL I S O U S -A R M O I R E LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.COM Pièces fournies Quantité 1 2 2 1 1 1 1 1 Partie Hotte Filtres à chicane pro LumiLight LED, 6 W (pré-installé) Col de transition rond de 8 po Collier rectangulaire 3-1 / 4 "x 10" avec amortisseur Moteur de soufflante simple (préinstallé) Plaque de recouvrement supérieure (pour gaine horizontale) Pack matériel (4) #6 x 2 po (4) #6 x 1-1/2 po (4) #6 x 1 po (4) M3.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine in. m po ax.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Hauteur de montage, dégagement et gaine Un conduit rond d’au moins 8 po ou un conduit rectangulaire de 3-1/4 po x 10 po est recommandé pour maintenir une efficacité maximale du débit d’air pour un seul ventilateur et un conduit rond de 10 po pour un double ventilateur interne. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
Instructions d’installation ZEPHYRONLINE.COM Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E ¯ Ů Haut 1-15/16 po 1-11/16 po 27-7/8 po ou 33-7/8 po *8-1/16 po **10-3/8 po 8-9/16 po 6 po *7-7/8 po * Conduit rond de 8 po ** Conduit rond de 10 po *** Gaine rectangulaire *9-1/2 po **14-3/16 po 9-7/8 po 11/16 po Arrière 1-15/16 po 7-3/8 po 1-1/4 po 3-3/16” 4-1/8 po ou 4-9/16 po 26 po ou 31-9/16 po 29-7/8 po ou 35-7/8 po Côté *14-1/16 po ***13-1/2 po *12-15/16 po **15-5/16 po 3 po 11 po 12 po * Co
Instructions d’installation ZEPHYRONLINE.COM Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Conversion de conduit horizontal Par défaut, le Tidal I est préconfiguré pour un conduit vertical rond de 8 po. Ces étapes sont pour des conduits horizontaux ronds de 8 po et rectangulaires de 3-1 / 4 po x 10 po. Si vous continuez avec un conduit vertical, veuillez ignorer ces étapes. REMARQUE: Le conduit horizontal n’est disponible que pour le ventilateur interne unique. 1. Débranchez la fiche du ventilateur. 2.
Instructions d’installation ZEPHYRONLINE.COM Conversion de conduit horizontal A B 4. Découpez les plaques arrière B pour un conduit arrière rond de 8 po ou la plaque A uniquement pour un conduit arrière rectangulaire de 3-1/4 po x 10 po. 5. Placez le ventilateur à l’intérieur de la hotte comme illustré. 6. Fixez le ventilateur au corps de la hotte à l’arrière de la hotte à l’aide des (4) vis de ventilateur précédemment retirées et rebranchez la fiche du ventilateur.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Horizontal Ducting Conversion 7. Fixez un collier de conduit rond de 8 po ou un collier de conduit rectangulaire de 3-1/4” po x 10 po à l’arrière du corps de la hotte à l’aide de (4) vis M3,5 x 8. 8. Depuis l’intérieur du corps de la hotte, placez la plaque de recouvrement supérieure vers le haut du corps de la hotte.
Instructions d’installation ZEPHYRONLINE.COM Installation de deux ventilateurs PBD-1300B Cette hotte de cuisinière est équipée de série d’une option de conduit vertical à un seul ventilateur. Pour passer d’un conduit vertical à une seule soufflante à un conduit vertical à double soufflante, veuillez suivre les instructions ci-dessous. Kit double soufflante PBD-1300B compatible uniquement avec AK7336AS. 1. Retirez les filtres déflecteurs et, le cas échéant, retirez les panneaux latéraux.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Installation de deux ventilateurs PBD-1300B 5. Installez le ventilateur précédemment retiré sur un côté de la plaque de ventilateur double et fixez-le à l’aide des (4) vis précédemment retirées de l’étape 2. 6. Installez le ventilateur du kit PBD-1300B sur l’autre côté de la plaque de ventilateur double à l’aide de (4) vis 3/16 x 3/8. 7. Emplacements de montage de deux vis de ventilateur. 8.
Instructions d’installation ZEPHYRONLINE.COM Installation de deux ventilateurs PBD-1300B 9. Reportez-vous à la section page 32 pour cette étape. Connectez le câblage du double ventilateur, y compris les deux fiches du ventilateur, le connecteur à 6 broches du câble du ventilateur (E), le câble du commutateur du ventilateur double (H), le cordon d’alimentation noir à une broche du double ventilateur (K) et le cordon d’alimentation blanc à une broche (F) au PCB double ventilateur. 10.
PRO Instructions d’installation TIDAL I S O U S -A R M O I R E Montage de la hotte Si la hotte à recirculation de la cuisinière, reportez-vous au manuel inclus avec le kit de recirculation ZRC-70xxC ou sur notre site Web avant d’installer la hotte. La hotte est conçue pour être installée sous une armoire de cuisine. Électrique 1. Préparez l’emplacement du conduit sur la hotte (vertical ou horizontal). Ouverture & découpe du conduit 2.
Fonctionnalités et commandes ZEPHYRONLINE.COM Contrôles de proximité Allumer Lumières ű Ù Ajuster 6 niveaux de vitesse CAPTEUR DE PROXIMITÉ Ź Lorsque vous vous approchez de la hotte lorsqu’elle est hors tension, les icônes d’alimentation, de diminution du ventilateur, d’augmentation du ventilateur et d’éclairage s’allument et «BONJOUR» apparaît sur l’écran LCD pendant 2 secondes. Ź Les icônes restent allumées pendant que le capteur de proximité détecte quelqu’un près de la hotte.
PRO Fonctionnalités et commandes TIDAL I S O U S -A R M O I R E Contrôles de proximité Lumières Ź Appuyez sur l’icône des lumières pour changer le niveau d’éclairage de 1, 2, 3, désactivé. AFFICHER ICÔNES et FONCTIONS Ů Ź L’icône de la cloche de notification s’allumera lorsqu’une action doit être entreprise. Appuyez sur l’icône pour parcourir les notifications. La cloche de notification restera allumée jusqu’à ce que toutes les notifications soient résolues.
Fonctionnalités et commandes ZEPHYRONLINE.COM Contrôles de proximité ¯Ů Ļ Ź La technologie de contrôle du flux d’air (ACT™) permet à l’installateur de régler le CFM maximum du ventilateur pour s’aligner sur les codes et réglementations locaux. Lorsque le ventilateur est éteint, appuyez et maintenez pendant 3 secondes pour afficher l’état ACT™. Ź ACT 290 = 3 vitesses, ACT 390 = 4 vitesses, ACT 590 = 5 vitesses.
PRO Fonctionnalités et commandes TIDAL I S O U S -A R M O I R E Zephyr Connect Votre hotte de cuisine est compatible avec notre application Zephyr Connect. Tout ce dont vous avez besoin est une connexion WiFi avec accès à Internet qui peut atteindre l’emplacement de votre hotte. Zephyr Connect vous permet de contrôler votre hotte de cuisine de n’importe où à l’aide d’un appareil mobile ou de votre enceinte intelligente Amazon Alexa ou Google Home.
Fonctionnalités et commandes ZEPHYRONLINE.
PRO Fonctionnalités et commandes TIDAL I S O U S -A R M O I R E Télécommande RF en option Pour commander la télécommande RF, la référence est 14000005. Le fil d’antenne bleu doit être rallongé pour un signal optimal. Veuillez consulter la section, Montage de la hotte, pour les instructions. Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement.
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF en option Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. C. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile. Remarque: le support de télécommande ne charge pas la télécommande RF.
PRO Entretien TIDAL I S O U S -A R M O I R E Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
Entretien ZEPHYRONLINE.COM Ů ¯ů ĕ Ę 1. Poussez le filtre vers l’avant de la hotte à l’aide des poignées. 2. Faites pivoter l’arrière du filtre vers le bas. 1 3. Retirez le filtre en l’éloignant de la hotte.
PRO Entretien TIDAL I S O U S -A R M O I R E LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées. Ĭ Ę ĭė 1. Retirez les filtres déflecteurs professionnels. 2. (Le cas échéant) Retirez les deux panneaux d’espacement par 2 vis pour chaque panneau d’espacement. 3.
Conversion ACT™ ZEPHYRONLINE.COM Ù ¯ Ġ Ĭ Ļĭ Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisinière peut déplacer. ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de kits d’air d’appoint coûteux. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des trois niveaux CFM les plus couramment spécifiés; 590, 390 ou 290 CFM.
PRO Conversion ACT™ TIDAL I S O U S -A R M O I R E Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes illustrées à la FIG. J. 2. Changez le positionnement du cavalier en plastique comme illustré à la FIG. K pour régler le CFM maximum souhaité du ventilateur. 3. Réinstallez la carte de circuit imprimé et poursuivez l’installation de la hotte. 4.
Conversion ACT™ ZEPHYRONLINE.COM Activer ACT™ 1. Carte électronique située derrière le panneau lumineux. 2. (Le cas échéant) Retirez les deux panneaux d'espacement par 2 vis pour chaque panneau d'espacement. 3. Retirez les 4 vis fixant le panneau lumineux. FIG.
PRO Schéma de câblage TIDAL I Schéma Blanc Noir Vert S O U S -A R M O I R E Corps Noir Rouge Noir Souffleur simple Moteur Corps ANT Blanc Noir Vert Blanc LED LED WIFI BLANC BLANC NOIR A. Fil de connexion Wi-Fi C.Câble d’alimentation pour PCB d’extension D.Câble d’alimentation pour PCB d’extension E. Fil de connexion du ventilateur F. Fil de connexion du ventilateur G. Fil de connexion de contrôle H. Circuit imprimé à double ventilateur pour passer le fil I. Cordon d’alimentation J.
Dépannage ZEPHYRONLINE.COM Problème possible Après l'installation, l'appareil ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L'unité vibre. L'unité siffle. Le ventilateur fonctionne, mais les LED LumiLight ne le sont pas. Cause possible Solutions La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement.
PRO Dépannage TIDAL I S O U S -A R M O I R E Problème possible La hotte ne s'échappe pas correctement. Cause possible Utilisation de la mauvaise taille de conduit. Changer le conduit à la bonne taille. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la plaque de cuisson et le bas de la hotte dans les limites de 24 po et 34 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible La hotte ne se connecte Le routeur ou le modem de pas au Wi-Fi. l’utilisateur est désactivé. Le routeur de l’utilisateur est connecté à une fréquence sans fil de 5 GHz. Les câbles coaxiaux de l’utilisateur sont desserrés. Le Wi-Fi sur le téléphone de l'utilisateur est désactivé. L'utilisateur se connecte au mauvais réseau Wi-Fi. La hotte n'est pas à portée de la connexion Wi-Fi. Des obstacles bloquent la force du signal Wi-Fi.
PRO Liste des pièces et accessoires TIDAL I S O U S -A R M O I R E La description Pièces de rechange LumiLight LED, 6 W Filtre Baffle Pro (chacun) Accessoires optionnels Double ventilateur interne Kit d'air d'appoint (ventilateur simple) Kit d'air d'appoint (double ventilateur) Télécommande RF Cache-conduit 30 po x 12 po Cache-conduit 36 po x 12 po Cache-conduit 30 po x 24 po Cache-conduit 36 po x 24 po Numéro d’article Z0B0048 50210039 PBD-1300B MUA008A MUA010A 14000005 AK0720 AK0726 AK1720 AK1726 Po
Garantie limitée ZEPHYRONLINE.
PRO Enregistrement du produit TIDAL I S O U S -A R M O I R E Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.