Installation Guide

11
This range hood is equipped standard with a 8” round vertical duct option. To convert from 8” round vertical to 8”
round horizontal ducting or 3-1/4” x 10” rectangular horizontal ducting please following the instructions below.
NOTE: Horizontal ducting is only available for the single internal blower.
127(,IKRUL]RQWDOO\GXFWLQJYLD´[´UHFWDQJXODUGXFWLQJWKHPD[LPXPDLUÀRZRI&)0ZLOO
be reduced to 550 CFM. Other CFM levels will not be affected.
VERTICAL TO HORIZONTAL DUCTING CONVERSION
1. Disconnect blower plug.
5HPRYHVFUHZVDWWRSRIKRRGERG\DWWDFKLQJ
blower to blower plate. Remove blower from
interior of hood body.
 5HPRYHVFUHZVIURPLQWHULRURIKRRGERG\
attaching blower plate to hood body. Remove
blower plate.
4. Knock out rear plates A & B for 8” round
rear ducting or plate B only for 3 1/4” x 10”
rectangular rear ducting.
A
B
Installation – Horizontal Conversion