Use, Care, and Installation Guide www.zephyronline.com Tempest I AK7000BS AK7036BS AK7042BS Model number: Serial Number: Date of Purchase: Sales Dealer: APR14.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... 6SHFL¿FDWLRQV ............................................................... Mounting the Range Hood ...................................... Horizontal Conversion............................................... PBD-1200A Dual Blower..........................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. No for use over an outdoor grill. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 6” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap x( ) = Ft. 7”-10” Round, 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft. 3-1/ 4” x 10” rect.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only.
Installation – 6SHFL¿FDWLRQV www.zephyronline.com *9 1/2” or **14 3/16” *8 1/8” or **10 3/8” 4 9/16” 12” 1 5/8” 6” 2” 8 9/16” 37˚ **15 5/16” 11” 3” 1” *7 7/8” or **9 15/16” 22 1/2” R 9/16” side 29 7/8” (30”) 35 7/8” (36”) 41 7/8” (42”) * Single Blower Dimension ** Dual Blower Dimension top 11/16” 4 9/16” 7 3/8” 1 1/4” 9 7/8” 4 1/16” 4 9/16” 3 1/4” 2 3/16” rect.
WARNING $OO (OHFWULFDO ZRUN PXVW E\ SHUIRUPHG E\ TXDOL¿HG HOHFWULFLDQ RU SHUVRQ ZLWK VLPLODU WHFKQLFDO NQRZ how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Mounting the Range Hood www.zephyronline.com For dual blower installation instructions please refer to page 13. If recirculating range hood refer to the manual included with ZRC-07xxxB recirculating kit or on our website prior to installing hood. Recirculating kit compatible with 650cfm single internal blower only. 5.
127( ,I KRUL]RQWDOO\ GXFWLQJ YLD ´ [ ´ UHFWDQJXODU GXFWLQJ WKH PD[LPXP DLUÀRZ RI &)0 ZLOO be reduced to 550 CFM. Other CFM levels will not be affected. VERTICAL TO HORIZONTAL DUCTING CONVERSION 5HPRYH VFUHZV DW WRS RI KRRG ERG\ DWWDFKLQJ blower to blower plate. Remove blower from interior of hood body. 1. Disconnect blower plug. A B 5HPRYH VFUHZV IURP LQWHULRU RI KRRG ERG\ attaching blower plate to hood body. Remove blower plate. 4.
Installation – Horizontal Conversion www.zephyronline.com 5. Place blower inside hood as shown. 6. Attach blower to hood body from the back of KRRG XVLQJ SUHYLRXVO\ UHPRYHG EORZHU screws and reconnect blower plug. 7. Attach 8” round duct collar or 3 1/4”x10” rectangular duct collar to back of hood body XVLQJ 0 [ VFUHZV 8. From inside hood body, position top cover plate to top of hood body.
1. Disconnect blower plug. 5HPRYH VFUHZV DW WRS RI KRRG ERG\ DWWDFKLQJ blower to single blower plate. Remove blower from hood body. 5HPRYH VFUHZV IURP LQVLGH KRRG ERG\ attaching single blower plate. Remove single blower plate from hood body. 4. Install dual blower plate from PBD-1200A kit LQWR KRRG ERG\ $WWDFK E\ VFUHZV SUHYLRXVO\ removed from step 3. 6. Install blower from PBD-1200A kit onto other VLGH RI GXDO EORZHU SODWH E\ [ screws. 5.
Installation – PBD-1200A Dual Blower www.zephyronline.com 7. Dual Blower screw mount locations. 8. Connect blower wire extrension cable from PBD-1200A kit to new blower. Connect both blower plugs. 3ODFH ´ URXQG DGDSWHU LQFOXGHG ZLWK 3%' $ RQ WRS RI KRRG DQG VHFXUH ZLWK M3.5 x 8 screws. NOTE: To secure the 10” transition adapter to top of hood a cut out of 14 1/2” width x 10 1/2” depth will need to be made in the cabinet bottom.
Display (speed level, delay off, filter clean) Lights On/Dim/Off Adjust 6 Speed Levels 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. ACT Verification - Airflow Control Technology (ACT) allows the installer to set the maximum blower CFM to align with local codes and regulations. - To verify the maximum blower CFM: - With hood off, hold the button for 3-4 seconds. If number 6 displays = default max.
Features & Controls – Touch Controls & Features www.zephyronline.com Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal filters are required to be replaced after every 120 hours of use. The charcoal filters should never be cleaned or placed in a dish washer.
Baffle Filter Clean Indicator When F flashes on the display, the baffle filters needo be cleaned. This will occur after every 30 hours of use. Clean Filters display < F > flashes F Reset the filter clean reminder timer after filters are cleaned and re-installed. With hood off, press and hold for approximately 5 seconds until F on display disappears . The filter clean reminder function is now reset and a new 30 hours elapse cycle is initiated. To Reset hold 5 sec.
Features & Controls – Optional Remote Control www.zephyronline.com FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
Wiring Diagrams www.zephyronline.com USE ONLY TYPE MR16, GU10, 35 W. MAX.HALOGEN LIGHT BULBS. AK7000BS, AK7036BS AK7042BS VOLTS HZ 120 60 CIRCUIT DIAGRAM ACT 390 CFM - Fan Max. 355W @ 2.8A ACT 290 CFM - Fan Max. 255W @ 2.
Fan Curve Diagrams Single Blower Fan Curve Diagram Dual Blower Fan Curve Diagram 23
Fan Curve Diagrams www.zephyronline.com ALUÀRZ &RQWURO 7HFKQRORJ\ $&7 Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed WR RQH RI WZR PRVW FRPPRQO\ VSHFL¿HG &)0 OHYHOV RU &)0 7KH XVDJH RI $&7 PD\ QRW EH necessary for your installation.
PART # Replacement Parts /LJKW %XOE 05 *8 : HDFK %DIÀH )LOWHU HDFK = % Optional Accessories 'XDO ,QWHUQDO %ORZHU .LW Z EORZHU 3%' $ 5HFLUFXODWLQJ .
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Tempest I AK7000BS AK7036BS AK7042BS Numéro de modèle : Numéro de série : Date d’achat : Détaillant: APR14.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit...................................................................................5 Espace libre et hauteur de montage...........................................................................6 Options d’installation pour le conduit..........................................................................7 6SpFL¿FDWLRQV........................................................................................................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION 3RXU UpGXLUH OHV ULVTXHV G¶LQFHQGLH HW SRXU pYDFXHU O¶DLU FRQYHQDEOHPHQW DVVXUH] YRXV GH FDQDOLVHU O¶DLU j O¶H[WpULHXU GH la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage. Cet appareil n’est pas conçu pour être utilisé à l’extérieur.
Liste du matériel www.zephyronline.
pi 3-1/ 4” x 10” 1 pi rect., droit x( 6” circ., droit 1 pi x( ) = pi 7” circ., droit 1 pi x( ) = pi 3-1/ 4” x 10” 15 pi rect., coude à 90º x( ) = pi 3-1/ 4” x 10” 9 pi rect., coude à 45º x( ) = pi 3-1/ 4” x 10” 24 pi rect., coude plat à 90º x( 3-1/ 4” x 10” 30 pi x( ) = Longueur x Nombre utilisé Pièces de conduit Total Total 30 pi x( ) = pi 6” chapeau de toiture circ. 30 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 1 pi x( ) = pi 6” circ. à 16 pi rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage de la surface de la FXLVLQLqUH DX EDV GH OD KRWWH QH GHYUDLW SDV rWUH inférieure à 26”. La hauteur de montage maximale ne devrait pas outrepasser 36”.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison.
Installation – 6SpFL¿FDWLRQV www.zephyronline.com *9 1/2” ou **14 3/16” *8 1/8” or **10 3/8” 4 9/16” 12” 1 5/8” 6” 2” 8 9/16” 37˚ **15 5/16” 11” 3” 1” *7 7/8” or **9 15/16” 22 1/2” R 9/16” Côté 29 7/8” (30”) 35 7/8” (36”) 41 7/8” (42”) * Dimensions pour le ventilateur simple ** Dimensions pour le ventilateur double Dessus 11/16” 4 9/16” 7 3/8” 1 1/4” 9 7/8” 4 1/16” 4 9/16” 3 1/4” 2 3/16” L/C rect. L/C circ.
AVERTISSEMENT 7RXV OHV WUDYDX[ pOHFWULTXHV GRLYHQW rWUH UpDOLVpV SDU XQ pOHFWULFLHQ TXDOL¿p RX XQH SHUVRQQH DYHF l’expérience technique et le savoir-faire nécessaires. Pour votre sécurité, enlevez le fusible ou éteignez le disjoncteur de circuit avant de commencer l’installation. 1¶XWLOLVH] SDV GH UDOORQJH pOHFWULTXH RX G¶DGDSWDWHXU DYHF FHW pOHFWURPpQDJHU Suivez le code électrique national ou les codes et réglementations en vigueur.
Installation – Installation de la hotte www.zephyronline.com Veuillez vous rapporter à la page 13 pour obtenir les instruction d’installation d’un ventilateur double. Si vous utilisez le mode de recirculation d’air, consultez le manuel accompagnant la trousse de récupération d’air ZRC-07xxxB ou notre site Web avant de procéder à l’installation de la hotte. La trousse de recirculation d’air n’est compatible qu’avec les ventilateurs internes simples de 650 pi3/min. 5.
NOTE : Si vous souhaitez installer un conduit horizontal rectangulaire de 3-1/4” x 10”, le débit d’évacuation d’air maximal de 650 pi3/min sera réduit à 550 pi3/min. Il n’y aura pas de conséquences sur les autres niveaux de pi3/min. CONVERSION D’UN CONDUIT VERTICAL À UN CONDUIT HORIZONTAL (QOHYH] OHV TXDWUH YLV GH OD SDUWLH VXSpULHXUH GH OD KRWWH TXL UHWLHQQHQW OH YHQWLODWHXU j OD SODTXH 5HWLUH] OH YHQWLODWHXU GH O¶LQWpULHXU GX bâti de la hotte.
Installation – Conversion horizontale www.zephyronline.com 5. Placez le ventilateur à l’intérieur de la hotte, comme illustré. 6. Fixez le ventilateur au bâti de la hotte à partir GH O¶DUULqUH GH OD KRWWH j O¶DLGH GHV TXDWUH vis de ventilateur préalablement enlevées et UHEUDQFKH] OD ¿FKH GX YHQWLODWHXU 7. Fixez le collier de conduit circulaire de 8” ou UHFWDQJXODLUH GH ´[ ´ j O¶DUULqUH GX EkWL GH OD KRWWH j O¶DLGH GH TXDWUH YLV 0 [ 8.
La trousse du ventilateur double PBD-1200A est compatible avec les modèles AK7036BS et AK7042BS. 'pEUDQFKH] OD ¿FKH GX YHQWLODWHXU (QOHYH] OHV TXDWUH YLV GH OD SDUWLH VXSpULHXUH GH OD KRWWH TXL UHWLHQQHQW OH YHQWLODWHXU j OD SODTXH GX YHQWLODWHXU VLPSOH 5HWLUH] OH ventilateur du bâti de la hotte. (QOHYH] OHV TXDWUH YLV GH O¶LQWpULHXU GH OD KRWWH TXL UHWLHQQHQW OD SODTXH GX YHQWLODWHXU VLPSOH DX EkWL 5HWLUH] OD SODTXH GX YHQWLODWHXU simple du bâti de la hotte.
Installation – Ventilateur double PBD-1200A www.zephyronline.com 7. Emplacements des vis du ventilateur double. 8. Branchez le câble d’extension de la trousse PBD-1200A kit au nouveau ventilateur.
Lumières Allumer/Veilleuse/Éteindre Choix de 6 vitesses Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1. Vérification de la ACT - La technologie de contrôle du débit d’air permet à l’installeur d’ajuster la quantité maximale d’évacuation de pi3 /min du ventilateur afin de respecter les codes et règlements en vigueur.
Commandes - &RPPDQGHV j HIÀHXUHPHQW HW FDUDWpULVWLTXHV www.zephyronline.com Indicateur de changement des filtres à charbon (si installés) Lorsque la hotte est installée en mode de récupération d’air, elle est munie d’un jeu de filtres à charbon conçus pour purifier la fumée de cuisson et remettre l’air en circulation dans la maison. Ces filtres à charbon doivent être remplacés toutes les 120 heures d’utilisation. Ne nettoyez jamais des filtres à charbon et ne les mettez jamais au lave-vaisselle.
Indicateur de nettoyage des filtres déflecteurs Lorsque l’icône F se met à clignoter sur l’afficheur, les filtres déflecteurs doivent être nettoyés, car 30 heures d’utilisation se sont écoulées. Une fois que les filtres ont été nettoyés et réinstallés, réinitialisez l’indicateur de nettoyage des filtres (avec la hotte hors tension). Lorsque la hotte est éteinte, appuyez environ 5 secondes sur la touche F jusqu’à ce que l’icône disparaisse.
Commandes – Commande à distance optionnelle www.zephyronline.com Mise en garde de la FCC : Dans le but d’assurer une conformité continue, toute modification apportée sans l’approbation expresse du parti responsable de la conformité pourrait annuler l’autorisation de l’utilisateur de faire fonctionner cet appareil. (Exemple – N’utilisez que des câbles d’interface armés lors du branchement à un ordinateur ou à un périphérique.) Cet appareil respecte l’article 15 des réglementations FCC.
1HWWR\H] UpJXOLqUHPHQW OHV VXUIDFHV GH OD KRWWH DYHF GH O¶HDX VDYRQQHXVH FKDXGH HW XQ FKLIIRQ GH FRWRQ propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. N’utilisez pas de produits à blanchir au chlore ou d’agents nettoyants « orange ».
Entretien – Lumières www.zephyronline.com REMPLACEMENT DES AMPOULES ATTENTION : Les ampoules deviennent extrêmement chaudes lorsqu’allumées. Veuillez NE PAS les toucher avant de les avoir éteintes et laissées refroidir. Le contact avec les ampoules chaudes pourrait causer de sérieuses brûlures. $VVXUH] YRXV TXH O¶DOLPHQWDWLRQ pOHFWULTXH HVW FRXSpH HW TXH OHV DPSRXOHV QH VRQW SDV FKDXGHV Enlevez les ampoules en les dévissant dans le sens contraire des aiguilles d’une montre.
Problème Cause Solution $SUqV l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé $VVXUH] YRXV TXH O¶DOLPHQWDWLRQ GX GLVMRQFWHXU et de l’appareil est allumée /HV OXPLqUHV fonctionnent, mais le ventilateur ne tourne pas.
Schéma de câblage www.zephyronline.
'LDJUDPPHV GHV FRXUEHV FDUDFWpULVWLTXHV GHV YHQWLODWHXUV GRXEOHV 23 Diagrammes des courbes caractéristiques des ventilateurs 'LDJUDPPHV GHV FRXUEHV FDUDFWpULVWLTXHV GHV YHQWLODWHXUV VLPSOHV
Diagrammes des courbes caractéristiques des ventilateurs www.zephyronline.
PART # Pièces de remplacement $PSRXOH 05 *8 : XQLWp )LOWUH GpÀHFWHXU XQLWp = % Accessoires optionnels 7URXVVH GH YHQWLODWHXU GRXEOH DYHF YHQWLODWHXU 3%' $ 7URXVVH GH UHFLUFXODWLRQ G¶DLU ´ =5& %
AGRAFEZ VOTRE REÇU ICI Garantie limitée Une preuve de la date d’achat originale est nécessaire pour obtenir du service lorsque le produit est sous garantie POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Corporation (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont ex