Use, Care, and Installation Guide www.zephyronline.com Breeze I AK1124x, AK1100x, AK1136x Breeze II AK1200x, AK1236x Model number: Serial Number: Date of Purchase: Sales Dealer: FEB08.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Specifications ............................................................... Preparing Electrical .................................................... Preparing Electrical and Ducting .......................... Converting to Air Recirculating Mode ................. Mounting the Range Hood .....
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 6” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap x( ) = Ft. 7”-10” Round, 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft. 3-1/ 4” x 10” rect.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 24”. Maximum mount height should be no higher than 32”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Installation – Specifications www.zephyronline.com TOP 35-3/4” (36”) 29-3/4” (30”) 23-3/4” (24”) 1/2” 10” C/L 12-3/16” 8-5/8” 3-1/4” 10-7/8” 2” 9-1/16” elec. k/o 2” 1-3/8” 33-7/8” (36”) 27-7/8” (30”) 22-1/16” (24”) Air Recirculating Louver Plate 33-5/8” (36”) 27-5/8” (30”) 21-5/8” (24”) 5-1/2” elec.
WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Preparing Electrical and Ducting www.zephyronline.com 1. Remove filters 2. Remove cover from junction box to gain access to electrical wiring. 3. If using a cable lock, pry open the desired electrical knockout either on top or back of hood. Feed the wires through the cable lock. Some local codes require the use of a cable lock, check your local codes. 4. If using hood in air recirculating mode skip steps 4 and 5. 5.
NOTE: Skip the recirculating preparation pages if you are ducting the air out of your home. 1. Secure each of the (2) spring clips to the safety grille body (A). Do this by inserting the screw through the spring and into the clip. Secure each clip to the safety grille body by using a philips head screwdriver. An air recirculating kit (optional) must be purchased before using hood in recirculating mode. Recirculating kit - 0AK11-21001 Replacement filter - 0AK11-20001 2.
Installation – Converting to Air Recirculating Mode www.zephyronline.com NOTE: Skip this page if you are ducting the air out of your home. 5. Remove each of the 5 screws holding the (2) interior recirculating panels. 7. Place louvered recirculating plate over top opening and secure using the screws previously removed. 12 6. Remove (2) interior recirculating panels.
For Mounting Under a Kitchen Cabinet (Fig 1) 1. Select preferred duct location (vertical or horizontal). Duct opening cutout 2. Begin installation by removing the filters (if installed). 3. Reinforce cabinet with 1”x2” wood strips if additional strengthening is required or if cabinets are framed. duct/silver tape 4. Temporarily position the range hood in the desired mounting location. Measure and mark the mounting holes, duct and electrical locations with a pencil. 5.
Features & Controls – Controls & Features www.zephyronline.com Breeze I, AK11xx This switch turns the blower on and off and controls the speed selection. is off, is low speed, is medium speed and is high speed. Lights Off/Bright/Dim is off, is bright, is dim. Breeze II, AK12xx This button turns the motors on and off. It also shuts off power to the whole hood. If the lights are on and this button is pushed, they will also turn off. This button turns the lights on, off and also dims them.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly using a micro fiber or clean cotton cloth and with grain.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise to unscrew. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART # Replacement Parts Light Bulb R16 40W (each) Light Bulb PAR20 50W (each) Metal Filter, 24” hoods (each) Metal Filter, 30” and 36” hoods (each) Z0B0002 - incandescent bulb included with hood Z0B0001 - optional halogen bulb 50200013 50200012 Optional Accessories Recirculating Kit Replacement Charcoal Filter 0AK11-21001 0AK11-20001 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. Warranty TO OBTAIN SERVICE UNDER WARRANTY: or any Service Related Questions, please call: 1-888-880-8368 TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.