Use, Care, and Installation Guide V E N T I L A T I O N Breeze I, II AK1124S, W AK1100S, W, B AK1136S, W, B AK1200S, W, B AK1236S, W, B Model number: Serial number: 0AK11-70001 REV. 09/04 © Zephyr Corporation. www.zephyronline.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ...................................................................................... 4 Mounting Height and Clearance ....................................................................... 5 Ducting ..................................................................................................................................... 6 Specifications .....................................................................................................................
Important safety Notice www.zephyronline.com CAUTION To reduce risk of fire and to properly exhaust air, be sure to duct air outside - Do not vent exhaust air into spaces within walls, ceilings, into attics, crawl spaces or garages. CAUTION For general venting use only. Do not use to exhaust hazardous or explosive materials and vapors.. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
3 - Wire connector caps 18g 4 - Wood Screws 2” 4 - Wood Screws 1 1/2” 4 - Wood Screws 1” 4 - Washers NO DUCTING IS INCLUDED * Note: Zephyr recommends using 50LB EZ anchors if mounting hood onto drywall. These are not provided. but are readily available of most hardware stores.
Installation - Ductwork Calculation Sheet www.zephyronline.com Equivalent number length x used = Duct pieces Equivalent number length x used = Duct pieces Total Total 3 1/4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round wall cap with damper 30 Ft. x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap 30 Ft. x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3 1/4” x 10” rect. transition x( ) = Ft. 3 1/4” x 10” 15 Ft. Rect.
Maximum mount height should be no higher than 30". It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency. net width MIN. 22” MAX 30” If available, also refer to range manufacturer's height clearance requirements and recommended hood mounting height above range. Always check your local codes for any differences.
Installation - Ducting www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or DuctTape.
1 - 31/32" ) 9 - 1/16" 7 - 5/8" ") 1 - 31/32" 1 - 31/32" 10 - 53/64" .3 78 7 1 - 31/32" 12 - 13/64" 8 - 20/32" 9 - 1/16" 21 - 37/64" 9 - 1/16" 1 - 31/32" 1 - 31/32" 33 - 55/64" (36") 27 - 7/8" (30") 22 - 3/64" (24") 9 - 1/16" Installation - Specifications .
Installation - Preparing Electrical and Ducting www.zephyronline.com 1. Remove filters. 2. Remove cover from junction box to gain access to the electrical wiring. 3. If using a cable lock (not provided) pry open the desired electrical knockout, either on the top or the back. Feed the wires through the 3/4” cable lock. Note: Some local coded require the use of a cable lock, Duct Measurements check your local coded for this information. 4.
An air recirculation kit (optional) must be purchased in order to use the hood in air recirculation mode. 1. Attach each of the (2) spring loaded clips to the safety grill body. Do this by inserting the screw to the spring and into the bracket. Then screw it into the safety grill body. 2. Insert the carbon filter into the carbon filter holder and place it over the safety grill. 3. Secure the carbon filter holder to the safety grill body by slightly lifting and twisting the spring loaded clip.
Installation - Mounting the Hood www.zephyronline.com ELECTRICAL - WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances. Electrical Supply: This appliance requires a 120V 60Hz electrical supply.
1 Blower On/Off/Speed Selection III II I 2 Lights On/Off/Dim II 0 I 0 1 Blower On/Off/Speed Selection This switch turns the blower on and off and controls the speed selection. 0 is off, I is low speed, II is medium speed and III is high speed. 2 Lights On/Off/Dim 0 is off, I is bright, II is dim. Breeze II, AKI2XX 4 1 3 III II 2 I 1 On/Off This button turns the motors on and off. It also shuts off power to the whole hood.
Maintenance - Cleaning and Replacing Light Bulbs www.zephyronline.com Aluminum Mesh Filters: Clean frequently using hot water and a mild, non abrasive detergent. Filters are dishwasher safe. Carbon Filters: Clean carbon filters holder frequently with a damp cloth and mild detergent. DO NOT immerse carbon filter in water or put in dishwasher. The carbon filters should be replaced every 4 to 6 months under normal use. Hood Surface: Remove filters.
Check if unit has been plugged in, make sure that all power has been turned back on and all electrical wiring are properly connected. 2. Light is on but blowers are not turning at all or seems to be scraping on something. Blower blade unit might have been mounted too low and scraping the bottom or jammed. Loosen hex screw on blade unit and adjust to proper height. 3. When blowers are on, something seems to be loose and spinning around inside.
Warranty www.zephyronline.com TO OBTAIN SERVICE UNDER WARRANTY: or any Service Related Questions, please call: Staple your receipt here. Proof of the original purchase date is needed to obtain service under the warranty. 1-888-880-8368 TO OBTAIN SERVICE UNDER WARRANTY: You must present proof of original purchase date. Please keep a copy of your dated proof of purchase (sales slip) in order to obtain service under warranty.
Part# Light Bulb (R16 40W) Light Bulb (PAR20 35W) Telescopic Back Splash 30” SS AK0710 Telescopic Back Splash 36” SS AK0716 Air Recirculation Kit (w/carbon filter) 0AK11-21001 Carbon Filter Replacement 0AK11-20001 Aluminum Replacement Filters, 24”, 30” 0AK11-22001 Aluminum Replacement Filters, 36” 0AK11-22002 To order parts, visit us online at : www.zephyronline.com and go to the parts store.
Exploded View Diagram www.zephyronline.
Factory Description “From Exploded View” 17 Per Hood Exploded View Diagram Part