www.zephyronline.
www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 23 CAMPANA EXTRACTORA - Manual de utilización...Pag. 45 CAPPA ASPIRANTE - istruzioni per l’uso...Pag.
LIST OF MATERIALS...........................................................................................................pag. 7 DUCTING CALCULATION SHEETS...............................................................................pag. 8 HOOD SPECIFICATION.....................................................................................................pag. 9 INSTALLATION - INTERNAL BLOWER.....................................................................................pag.
Safety instructions www.zephyronline.com IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents.
WARNING – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: A. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out mmediately, EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN – You may be burned. C. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result. D. Use an extinguisher ONLY if: 1.
Safety instructions www.zephyronline.com through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D.
Glass Electrical Junction Box Range Hood Body Glass Control Decorative Mesh Filters Light Bulbs TYPE DESCRIPTION N° A M4 1+1 B 1/8" x 1/4" 12 C 1/8" x 2/4" 4 D 1/4" x 2-3/4" 6 -7- List of Materials Top Cover
Ducting Calculation Sheet www.zephyronline.com Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.
top of hood -9- Hood Specifications side of hood front of hood
Installation - Internal Blower www.zephyronline.com NOTE! The device in this version (with internal suction blower) is equipped for rear discharge of exhaust air. However, if required, it is possible to have the exhaust air discharged from the top. This can be accomplished by carrying out the steps indicated in the following paragraphs; upon reaching step 4, the motor plate must not be rotated. The following instructions are for installing the internal blower.
Installation - Internal Blower 4. Rotate the blower plate (Note! If air is discharged from the top, do not rotate the plate).Place the 6" metallic flange on the blower's air outlet (the flange may already be pre-installed). Install internal blower into blower plate and secure using (4) screws included with the blower. See Fig.4 5. Fasten the two brackets to the sides of the blower by fixing them onto the blower plate with the (4 type B) screws, and to the sides of the blower with other (4 type C) screws.
Installation - Internal Blower www.zephyronline.com 8. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex connector located inside the blower housing. See Fig.8 9. Install the blower and plate on the inside of the blower housing: carry out the instructions at step 3 in reverse order then use the screws provided to complete installation. (Tot. 12 type B). Fig.9 10. Open the flap Fig.10.
The following instructions are for preparing the hood for use with an external or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fire and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 10. 1. Unclip the top cover. Fig.1 2. Remove the metal blower plate by striking it with the aid of a slotted screwdriver Fig.2 3.
Installation - External & In-Line Blower Preparation www.zephyronline.com 5. Install the plate with the flange facing the wall, inside the motor casing: carry out the instructions at stage 3 in reverse order then use the screws provided to complete installation. (Tot. 12 type B). (Note! If air is discharged from the top, rotate the plate and install it in the opposite direction with the flange facing upwards) Fig.5 6. Put the top cover back on. 7. Open the flap Fig.6 8.
Note: Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. Note1: A cable lock (not included) may be required by local codes. Please review local codes for more information. 11. Attach 6 pin male molex connectors to 6 pin female molex connectors inside blower housing. See Fig. 9 Note2: Check local codes to determine minimum wire gauge. See manual included with external and in-line blower for instructions on installing the blower.
Installation - Ducting Options www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
The range hood must be installed at a minimum height of 22 inches (56 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance. Before proceeding with the assembly instructions remove the decorative mesh filters so that the range hood is easier to handle. Min 22" - Max 34" 36" MOUNTING TO THE WALL 1.
Installation - Mounting the Range Hood www.zephyronline.com 3. Lift the hood onto the screws (type D) and adjust to make sure the hood is level. 4. When the hood has been adjusted tighten the screws to secure the hood in place. NOTE: Screws must be fastened into wooden studs so wood blocking may be necessary. If using wall anchors make sure to check your local codes for suitability and type of anchors to use.
POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 1. Open the flap Fig.16 2. Remove the power supply cover by undoing the (2) screws Fig. 17. 3. Connect the wires of the hood to those of the power supply as described. Fig.18 : BLACK = L line WHITE = N neutral GREEN / YELLOW = G ground - A double-pole switch properly rated must be installed to provide the range hood power supply disconnection.
Maintencance www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance. • The decorative mesh filters capture the grease particles suspended in the air and are therefore subject to clogging because of frequent use.
HOOD PART# REPLACEMENT PARTS Light Bulb GU5, 20W (each) AHZ Z0B0031 Recirculating Kit AHZ ZRC-00HZ Replacement Charcoal Filters AHZ Z0F-00AC Short Duct Cover (8”-9” ceiling) AHZ Z1C-00HZ Long Duct Cover (9”-10” ceiling) AHZ Z1C-01HZ Black Glass with Flower Pattern AHZ AHG-00BL White Glass with Leaf Pattern AHZ AHG-00WG OPTIONAL ACCESSORIES To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
www.zephyronline.