Instruction manual

22
b. Utilize film back interchangeability and expose the frame after
removing the film back from the main body. Then, continue shooting,
according to "a". (See 3. Attachment and Removal of Film Backs.)
A. The focusing screen can be exchanged, depending on the type of
photographic work being undertaken. First, remove the finder
attached to the main camera body. Next, move the screen removal
levers on both sides in the arrow-indicated directions, as illustrated.
Then, using a pincer or similar tool, lift up the screen with the protru-
sion at the rear end.
B. To install the focusing screen, insert the protrusion at the rear end
of the screen in a corresponding groove on the main camera body.
Then, slide both screen removal levers forward to secure the focusing
screen.
* Seven types of focusing screens are available for the Zenza Bronica
SQ-Ai.
The film-winding crank assembly must be removed for attaching the Motor Drive SQ-I or
the Speed Grip S to the main camera body.
A. Lift up the release lever on the base of the film-winding crank
assembly.
24. Mirror Lock-Up (con’t)
25. Interchanging Focusing Screens
26. Removal and Attachment of the Film Winding Crank Assembly