User's Manual

Figure 29Figure 28
SET SCREW
RED RESET
BUTTON
NO PRESSURE ON
LOAD CELL
1 MM BETWEEN SET SCREW
AND LOAD CELL
COUNTER NUTLOAD CELL
BRACKET
Figure 27
15
CALIBRATION
BODY BIKE Connect is able to
measure extremely accurately
due to the unique brake unit.
However, the way the brake
pad settles on the ywheel
will aect the measurements
slightly. Therefore it may be
necessary to adjust the set
screw as the Kevlar wears in
order to obtain full advantage
of the high level of accuracy.
1: Remove the right service
hatch, see gure 15 on page 10.
2: Release all tension and push
the brake unit back on the shaft,
see gure 27.
3: Slowly add tension without
touching the brake unit. The
brake unit will automatically
move forward on the shaft until
the brake block arc settles on
the ywheel curvature.
4: When the brake unit has
settled, adjust the set screw to
obtain 1mm space between the
load cell and the set screw, see
gure 28. Tighten counter nut.
Move the load cell bracket if
the adjustment of the set screw
is not adequate. Be careful not
to over load the load cell by
pulling or twisting it.
5: Tighten the counter nut, see
gure 28.
6: 0-calibrate the load cell by
pressing the red reset button
on the control box, see gure
29. Make sure nothing is
pressing on the load cell when
0-calibrating.
7: Remount the service hatch.
BODY
BIKE
®
INDOOR CYCLE
15
MAINTENANCE