Operation Manual
- 17 -
1. Switch the remote control to【Setting Mode】。
2. Enter the Upper Limit Setting Mode:
Press【Up】and【Stop】simultaneously; when the motor responds with a “beeping”
sound, it enters the Upper Limit Setting Mode.
3. Set the Upper Limit:
Use remote control to lift blinds at the target position for setting the upper limit.
During this operation, please perform【Switch Between Forward and Backward
Rotations】if necessary.
Press【Stop】and【Enter】 simultaneously; when the motor responds with a
“beeping” sound, the upper limit setting is complete.
Set Upper/Lower Limit
Press【Stop】
and
【
Enter
】
simultaneously
Beep
Press【Up】and【Stop】
simultaneously.
Beep