User Guide
Table Of Contents
- Contents
- Document updates
- 1 Introduction
- 2 Configuration
- 2.1 General
- 2.2 Display
- 2.3 Inputs
- 2.4 Thermostat n
- ANNEX I. Video Intercom Operation
- ANNEX II. Internal Call Operation
- ANNEX III. Remote Control via IP
- ANNEX IV. Graphs
- ANNEX V. Differences with Z50 / Z100
- ANNEX VI. Communication Objects
Z50 / Z70 v2 / Z100
https://www.zennio.com Tecnical Support: https://support.zennio.com
51
Unit with Camera [disabled / enabled]: define whether the installed video
intercom has camera.
Outdoor Unit ID [ID_n]: alphanumerical identifier of GetFace IP (field Phone
Number (ID), in Services
→
Phone).
Note: the characters included in this field must comply RFC 2396 standard.
Set Static IP [disabled / enabled]. If Z70 v2 and GetFace IP are in different
networks, IP Address [192.168.1.201] of GetFace IP must be set, in addition to
Specifying Gateway, in “IP Configuration” tab (see section 2.1.12).
Opening Settings:
➢ HTTP Command Secure Opening [
disabled/enabled]: the order to open a
door will be sent via a HTTP command. Setting a username and a
password will be required (must match with the ones set in GetFace IP in
section Services
→
HTTP API).
➢ KNX Object [
disabled / enabled]: enables the 1-bit object “[VI n] Switch n”
by means of which the output of a KNX actuator with the door lock
connected to it can be controlled. Choosing the Object Value [
1 = Open / 0
= Open] that will open the door is possible.
➢ Automatic Door Opening (DOORMATIC) [disabled/enabled]: enables the
door/s to be opened automatically when receiving a call.
• Initial Status (After Download) [Disabled /
Enabled]: sets whether the
automatic opening is enabled or not after ETS Download. It also can be
changed at runtime through the object “[VI n] Enable Automatic Door
Opening”.
• Disable if “Do Not Disturb” Mode Is Active [disabled/
enabled]: disables
the automatic door opening when do not disturb mode is active.
• Opening Delay [
0…255] [x 1s]: set a time after which the automatic door
opening command will be sent.
➢ Enable KNX Objects to Trigger Opening [
disabled/enabled]: enables the
1-bit object “[VI n] Trigger Switch n” which can open the door by writing on