User Guide

Table Of Contents
Z50 / Z70 v2 / Z100
https://www.zennio.com Tecnical Support: https://support.zennio.com
28
Password 2 [Enter Password 2]: message shown when the user is
required to type in the password for level 2.
Error [
ERROR]: message shown to the user when the typed password is
not valid.
New Password [
New Password]: message shown to ask the user for a
new password, during the password change process.
Repeat Password [
Repeat Password]: message shown when the user is
required to re-type the new password.
Password Updated [
Updated]: message shown to the user as a
confirmation of the password change.
2.1.5 SCHEDULERS
Z70 v2 offers the possibility to enable up to 30 schedulers, within which the execution
of up to 30 timed sending actions to the KNX bus can be configured.
Timed actions are performed on the programmable controls that have been configured
in the device:
1-Button Controls:
Switch.
Scene
Two Object (Short Press/Long
Press
2
).
Hold & Release.
Enumeration.
Constant (Counter / Scaling / Float).
2-Button Controls:
Switch.
Two Object (Short Press/Long
Press
2
).
Counter.
Scaling.
Float.
Enumeration.
Shutter.
Dimmer.
Climate Specific Controls:
Temperature Setpoint control.
Mode.
2
In the case of two-object controls (Short Press/Long Press), the schedulers only take into
account the short press value.
Special modes.
Fan.