User Guide

Table Of Contents
Z50 / Z70 v2 / Z100
https://www.zennio.com Tecnical Support: https://support.zennio.com
153
1 Bit
O
C R - T -
DPT_UpDown
0/1
[Cx] Shutter - Move Control
0 = Up; 1 = Down
4 Bit
O
C R - T -
DPT_Control_Dimming
0x0 (Detener)
0x1 (Reducir 100%)
...
0x7 (Reducir 1%)
0x8 (Detener)
0x9 (Subir 100%)
...
0xF (Subir 1%)
[Cx] Light - 4-bits Dimming
Control
4-Bit Dimming Control
1 Bit
I/O
C R W T U
DPT_Enable
0/1
[Cx] Fan - Auto Mode
Switch Auto Mode on Short
Press
1 Bit
I/O
C R W T U
DPT_Enable
0/1
[Cx] Fan - Auto Mode
Switch Auto Mode on Long Press
1 Byte
I/O
C R W T U
DPT_Scaling
0% - 100%
[Cx] RGB - Green Channel
0% ... 100%
1 Bit
O
C R - T -
DPT_Switch
0/1
[Cx] Chronothermostat - On/Off
Control
0 = Off; 1 = On
1 Byte
I/O
C R W T U
DPT_Scaling
0% - 100%
[Cx] RGBW - Blue Channel
0% ... 100%
507, 512, 517, 522, 527,
532, 537, 542, 547, 552,
557, 562, 567, 572, 577
2
Bytes
I
C - W T U
DPT_Value_Temp
-273,00º - 670433,28º
[Cx] Setpoint - Ambient
Temperature Status
-99ºC … 199ºC
1 Byte
I/O
C R W T U
DPT_Scaling
0% - 100%
[Cx] RGB - Blue Channel
0% ... 100%
1 Byte
I/O
C R W T U
DPT_Scaling
0% - 100%
[Cx] RGBW - White Channel
0% ... 100%
2
Bytes
O
C R - T -
DPT_Value_Temp
-273,00º - 670433,28º
[Cx] Chronothermostat -
Setpoint Control
-99ºC … 199ºC
1 Byte
O
C R - T -
DPT_Scaling
0% - 100%
[Cx] Shutter - Percentage
Control (Only Schedulers,
Macros and Voice Control)
0%=Top; 100%=Bottom
1 Byte
O
C R - T -
DPT_Scaling
0% - 100%
[Cx] Light - 1-Byte Percentage
Control (Only Schedulers,
Macros and Voice Control)
1-Byte Dimmer Control
508, 513, 518, 523, 528,
533, 538, 543, 548, 553,
558, 563, 568, 573, 578
4 Bit
O
C R - T -
DPT_Control_Dimming
0x0 (Detener)
0x1 (Reducir 100%)
...
0x7 (Reducir 1%)
0x8 (Detener)
0x9 (Subir 100%)
...
0xF (Subir 1%)
[Cx] RGBW - Light Dimming
Control
4-Bit Dimming Control
1404
1 Bit
I
C - W - -
DPT_DayNight
0/1
[General] Backlight Mode
0 = Night Mode; 1 = Normal
Mode
1 Bit
I
C - W - -
DPT_DayNight
0/1
[General] Backlight Mode
0 = Normal Mode; 1 = Night
Mode
1405
1 Byte
I
C - W - -
DPT_Scaling
0% - 100%
[Profile] Display - Brightness
0% ... 100%
1406
1 Byte
I
C - W - -
DPT_Scaling
0% - 100%
[General] Display - Contrast
0% ... 100%
1407
1 Bit
C - - T -
DPT_Trigger
0/1
[Heartbeat] Object to Send '1'
Sending of '1' Periodically
1408
1 Bit
I
C - W - -
DPT_Enable
0/1
[General] Proximity Sensor