Operation Manual

Z41 Pro
http://www.zennio.com Tecnical Support: http://support.zennio.com
16
controls stay hidden for the final user. These details are explained in section 3,
together with the entire parameterisation process.
2.5 BACKLIGHT
In order to prevent unnecessary power consumption while the device is idle, Z41
automatically fades partially out the backlight of the screen after a few minutes without
any user interaction. After that, if the inactivity persists for a few more minutes, the
backlight is completely turned off. While partially or totally faded out, any press on the
screen will bring back the normal light level.
The timings for the above behaviour may differ in case a pop-up window is open, as
well as depending on the configuration set in parameters (see section 3.2.1).
2.6 PAGE SHAPING
Each of the pages of the user interface including Menu and Profile can be
independently parameterised to display its control/indicator boxes statically distributed
or automatically ordered.
Static (grid) Distribution: all the 8 boxes of the page will be shown,
remaining empty those not having been assigned a function.
Figure 10 Static Distribution
Automatic Distribution: the active boxes will be dynamically ordered, so that
they make use of all the available space. The final distribution of the page will
therefore depend on the number of boxes with a function assigned.