Note: the default option is encouraged. Permanent illumination may affect
adversely the device lifetime, and is only intended for special circumstances.
Show Time: sets whether the current time (according to the internal clock)
should show in the upper left corner of every page. The default is “Yes”.
Show Temperature: sets whether the current temperature should show or
not in the upper right corner of every page, being necessary in such case to
choose the source of the temperature value: “Internal temperature probe” or
“External value”. If the latter is chosen, an object named [General] External
temperature will be enabled, so that it can be grouped with any other object
that sends temperature values.
Time/Date Sending Period: when enabled (value different from zero),
whenever the device is restarted, the date and time objects (“[General] Date
and “[General] Time”) will be sent to the bus, and thereafter, they will be sent
again every time the period expires. Setting a new time to the device either
through object or from the date/time configuration window will not restart the
count of the sending period. Range: [0-65535] x 1 min. The default value is
10 min.
Thermostat 1: checkbox (unselected by default) that activates/deactivates
the Thermostat 1 parameter screen. See section 3.7.
Thermostat 2: idem for Thermostat 2. See section 3.7.
Weekdays Initials (Mon... Sun): field that permits customising the label that
represents each of the weekdays within the configuration pages of the weekly
timers (see epigraph e) in section 3.4.2.5). A 7-character string (including
letters or numbers) should be entered, so each of the characters will
represent one weekday. The default value is “MTWTFSS”, according to the
initial letters of the day names in English.
Label for “Time ON”: field that permits customising the label that will be
shown within the configuration pages of the weekly timers (see epigraph e) in
section 3.4.2.5), next to the checkbox that enables/disables the sending of
the switch-on order. The default value is “Time ON”.
Label for “Time OFF”: field that permits customising the label that will be
shown within the configuration pages of the weekly timers (see epigraph e) in