Starting / Finish time: establishes the start time (hours and minutes) at
which the presence simulation will begin (and finish), provided that the
functionality needs to have been enabled first, by sending a “1” through the
"[Sim] Presence simulation" object.
Note: the start and finish times must be different; if not, the presence
simulation may behave unexpectedly.
Minimum/Maximum ON/OFF time: sets the minimum and maximum time
lengths desired for the ON and OFF states.
Note: the value set as maximum (both for the ON and the OFF states) must
be greater than the value set as minimum. If not, the presence simulation
may behave unexpectedly.