And the timers page 3 this way:
-Box 3 Linked to Scene number 11. Only for ON
In case that all these timers send their own scene at the same time, the only scene that will be
sent is the one linked to the last box of the last Timer page configured, in this example, Z38i
will send the scene number 11 (linked to the Box 3, in the Timers page 3).
Climate
Air Conditioning and Fan Coil Control have been unified in a unique Specific Page called
“Climate”. Thus, due to the possibility of enabling up to 4 different Climate Specific Pages, up
to 4 different Climate Systems can be now controlled from the Z38i. The control of them is
done from “Specific Pages 1, 2, 3 and 4”, after being enabled to this purpose.
It is possible to control the two internal thermostats of the panel through these specific Climate
pages. For this aim, it is necessary to properly link, via group addresses, the communication
objects of the Climate page with the objects associated to the different thermostat options.