Every enabled box for the timers control will have its own output "Channel" (output object of
the timers) through which the communication object in charge of controlling the timer will go.
The following parameters can be configured for every enabled box:
Name: This field allows a user to associate a name with the corresponding box in the
page. (11 free characters are available to set the name).
Linked to scenes: When this box is enabled, a user can control Scenes by mean of
a programming. The possible control associations are:
Only for ON: The Scene Number (On) box will appear where it is needed to
write the scene number to execute when the ON programming set by the user is
fulfilled.
Only for OFF: The Scene Number (On) box will appear where it is needed to
write the scene number to execute when the ON programming set by the user is
fulfilled.
Both timer ON and OFF: The Scene Number (On) box and Scene Number
(Off) will appear.
Note I: These associations are solved through internal links; this means it is not necessary
any kind of addressing process to carry out Schedule Programming associated to Scenes.
Note II: When many different schedule programming send different scenes at the same
moment, just one of them will be sent, specifically, the scene linked to the last box of the last
schedule programming page.
Please see the following example:
It is parameterized in ETS the specific pages 1 and 3 as Timer pages. The Timer page 1 is
configured like this:
- Box 2 Linked to scene number 64. Only for ON
- Box 3 Linked to scene number 1. Only for OFF
- Box 4 Linked to scene number 52. Only for ON