In this case, the Panel will not send any binary data to the bus unless the correct password is
entered.
Icon: A pair of icons can be associated to the page box.
Indicator: by activating this parameter, a status indicator will be inserted between
both buttons: Nothing, ON/OFF, 0/1
Presence simulator: This function is designed to simulate presence in a house. Once
the devices on the KNX installation have been correctly parameterized, two new
Communication Objects become active.
After enabling the presence simulation in ETS, two new 1-bit communication objects will be
shown: "[Home x - Box y] Presence simulator" and "[Home x - Box y] Simulation channel". The
first one allows activating or deactivating the presence simulation, by sending the value "1" or
"0", respectively. The second one is in charge of randomly sending binary values ("0" or "1") to
switch on/switch off the devices in the KNX installation, such as light or shutter controllers.
This object must be linked to the same group address as the corresponding control objects, in
charge of switching on/off the devices of the installation implied in the presence simulation.