Operation Manual

ZENNiO AVANCE Y TECNOLOGÍA vwww.zennio.com
24
24
Activate the Alarm System.
Once the scene is defined, every time we run it, a predefined atmosphere is generated.
How does a user modify and learn a scene, with the devices used in the scene described above?
For example if the user wants this instead:
Turn all the lights Off except one (the one to remain ON, will be a guiding light).
Turn Off the Heating and the A/C Systems
Activate the Alarm System.
The way to do this:
1. Run the scene to be modified.
2. Turn the light we want it to be the guiding light On
3. Just save the new scene into the Panel by keeping a long press (3 seconds) on
the original scene “Run” button.
This process replaces the original scene by the modified one.
Temperature control: This is a generic temperature control that allows selecting whether
to carry out an absolute temperature control (positive values) or a temperature control through
a temperature offset (positive and negative values, to be added to the current temperature
when receiving the order via the corresponding communication object). This control is totally
independent from the Climate Control.
Control type: To select between Absolute Temperature (default range [10ºC, 30ºC]
and associated objects “Temperature Control” and “Temperature indicator”) or
Temperature Offset (default range [-10ºC, 10ºC], and the same associated objects).