The shutter control is carried out as follows:
Decrease button: a long press moves down the shutter while a short press stops the
shutter, sending the value "1" through the objects "[Home x; Box y] Move shutter" and
"[Home x; Box y] Stop shutter", respectively.
Increase button: a long press moves up the shutter while a short press stops the
shutter, sending the value "0" through the objects "[Home x; Box y] Move shutter" and
"[Home x; Box y] Stop shutter", respectively.
Note: When the object “Move Shutter” sends “0” or “1”, the shutter will start moving, and won’t
stop unless the whole shutter length is covered or that any other order cancelling the previous
is received.
The available options are:
Icon: A pair of icons can be associated to the page box.
Indicator: by activating this parameter, it is possible to insert an indicator between
both buttons to get estimation in percentage terms of the shutter position.
Climate control: Designed specifically to control the functioning of air conditioning
devices without the need to access a specific climate page.
This can be very useful if there are free boxes in “Home” or “Home II” pages because that
way, the user will avoid browsing between the different pages and will have access directly to
determinate specific functions. It is possible to access to this (depending on the configuration
applied to the function):