Instruction manual

19
206-4081-C
LMT7Z7 : FTG Card Installation
ANTENNA
/CABLE
M.P. I.
Caution: Disconnect power cord from unit
before attempting to remove MPI card.
MPI Pass-thru Mode (Default)
1. Remove both retaining screws and partially pull
out current card from MPI slot so that the RF
cable can be disconnected.
2. Disconnect RF cable and totally pull out the
current card.
3. Partially slide the LMT7Z7 into the MPI slot.
4. Connect RF cable.
5. Fully slide the LMT7Z7 in so that the card seats
securely into the backplane connector
6. Install retaining screws.
FTG Mode Additional Steps
7. Wait at least 40 seconds after AC power is applied
to the system before turning the unit on.
8. The LMT7Z7 “Banner” will appear momentarily
on the TV screen, the first time the system is
turned on after AC power is applied, displaying
the firmware version.
DC IN
M.P. I.
Card Slot
ANTENNA
/CABLE
M.P. I.
RF CABLE
RF cable needs to be
connected when
LMT7Z7 is installed
.
Caution: Be sure
power cord remains
disconnected from unit
before attempting to
install LMT7Z7 card.
ANTENNA/CABLE INPUT
Receives RF signals
.
RETAINING SCREW
Install after inserting
the LMT7Z7 card.
RETAINING SCREW
Install after inserting
the LMT7Z7 card.
M.P.I. INTERFACE
Available MPI port
.
CONFIGURATION
INTERFACE
Use with LG configuration
software on PC
.